Code of Federal Regulations: Containing a Codification of Documents of General Applicability and Future Effect as of December 31, 1948, with Ancillaries and IndexDivision of the Federal Register, the National Archives, 1987 Special edition of the Federal Register, containing a codification of documents of general applicability and future effect ... with ancillaries. |
From inside the book
Results 6-10 of 100
Page 139
... LOADS FOR SHACKLES [ In tons of 2,000 pounds ] Material size ( inches 1.4 Pin diameter ( inches ) Safe working load 5/8 3/4 2.2 7/8 3.2 1 4.3 18 5.6 114 6.7 138 8.2 112 10.0 15/8 2 11.9 16.2 24 21.2 TABLE H - 20 - NUMBER AND SPACING OF ...
... LOADS FOR SHACKLES [ In tons of 2,000 pounds ] Material size ( inches 1.4 Pin diameter ( inches ) Safe working load 5/8 3/4 2.2 7/8 3.2 1 4.3 18 5.6 114 6.7 138 8.2 112 10.0 15/8 2 11.9 16.2 24 21.2 TABLE H - 20 - NUMBER AND SPACING OF ...
Page 139
... load in any position in the event the jack malfunctions . ( 2 ) If lift slabs are automatically controlled , a device shall be installed which will stop the operation when the 2 - inch leveling tolerance is ex- ceeded . ( c ) Blocking ...
... load in any position in the event the jack malfunctions . ( 2 ) If lift slabs are automatically controlled , a device shall be installed which will stop the operation when the 2 - inch leveling tolerance is ex- ceeded . ( c ) Blocking ...
Page 156
... load in- terrupting device or shall be provided with prominently displayed caution signs to prevent switching load cur- rent . ( B ) For series capacitors the proper switching shall be assured by use of at least one of the following ...
... load in- terrupting device or shall be provided with prominently displayed caution signs to prevent switching load cur- rent . ( B ) For series capacitors the proper switching shall be assured by use of at least one of the following ...
Page 159
... load current of the circuit shall be either inter- locked with a circuit interrupter or provided with a sign warning against opening them under load . ( 3 ) Mobile and portable equipment— ( i ) Power cable connections to mobile machines ...
... load current of the circuit shall be either inter- locked with a circuit interrupter or provided with a sign warning against opening them under load . ( 3 ) Mobile and portable equipment— ( i ) Power cable connections to mobile machines ...
Page 161
... Load ratings . In existing installa- tions , no changes in circuit protection shall be made to increase the load in excess of the load rating of the circuit wiring . ( d ) Fuses . When fuses are installed or removed with one or both ...
... Load ratings . In existing installa- tions , no changes in circuit protection shall be made to increase the load in excess of the load rating of the circuit wiring . ( d ) Fuses . When fuses are installed or removed with one or both ...
Other editions - View all
Common terms and phrases
abrasive wheels actinolite aerial lift angle of repose ANSI anthophyllite apply asbestos asbestos-containing blasting bracing cable chemical circuit construction containers cranes cylinder DECOMPRESSION TABLE designed device diameter disconnecting electrical employees enclosure energized ensure equivalent excavation exceed exposed exposure Federal feet fibers fire flammable floor fuel gas grounding conductor guarded Guardrails hazard HEPA hoist horizontal hose inches installed insulated jack ladders least less lines load maximum means ment metal minimum operations paragraph permitted person personal protective equipment phyllite planks platform ployees poles portable pounds Powder-actuated tools pressure prevent protective equipment rail rated removed requirements respirator roof rope safe Safety and Health safety data sheet scaffold secured shoring side slings spacing specific splices standard steel structure Subpart Table test subject tion Toeboards tractors trade secret tremolite valve vehicle ventilation vertical voltage volts welding wheels wire wire rope
Popular passages
Page 11 - State agency which is directly responsible for providing free public education for handicapped children (including mentally retarded, hard of hearing, deaf, speech impaired, visually handicapped, seriously emotionally disturbed, crippled, or other health impaired children who by reason thereof require special education...
Page 18 - When the daily noise exposure is composed of two or more periods of noise exposure of different levels, their combined effect should be considered, rather than the individual effect of each. If the sum of the following fractions: C1/T1 + C2/T2+ . . . Cn/Tn exceeds unity, then, the mixed exposure should be considered to exceed the limit value.
Page 12 - That the advertised specifications for every contract in excess of $2,000, to which the United States or the District of Columbia is a party, for construction, alteration, and/or repair, including painting and decorating, of public buildings or public works...
Page 11 - States to provide financial assistance ... to local educational agencies serving areas with concentrations of children from low-income families to expand and improve their educational programs by various means (including preschool programs) which contribute particularly to meeting the special educational needs of educationally deprived children.
Page 11 - States and local public bodies and agencies thereof in financing the acquisition, construction, reconstruction, and improvement of facilities and equipment for use, by operation or lease or otherwise, in mass transportation service in urban areas and in coordinating such service with highway and other transportation in such areas.
Page 137 - Overcurrent.") (91) Panelboard. A single panel or group of panel units designed for assembly in the form of a single panel; including buses, automatic overcurrent devices, and with or without switches for the control of light, heat, or power circuits; designed to be placed in a cabinet or cutout box placed in or against a wall or partition and accessible only from the front.
Page 137 - Concealed. Rendered inaccessible by the structure or finish of the building. Wires in concealed raceways are considered concealed, even though they may become accessible by withdrawing them. [See "Accessible. (As applied to wiring methods.)."] Conductor.
Page 12 - That no part of such contract will be performed nor will any of the materials, supplies, articles, or equipment to be manufactured or furnished under said contract be manufactured or fabricated in any plants, factories, buildings, or surroundings or under working conditions which are unsanitary or hazardous or dangerous to the health and safety of employees engaged in the performance of said contract.
Page 75 - Employers shall ensure that employees are provided with information and training in accordance with paragraph (h) of this section (except for the location and availability of the written hazard communication program under paragraph (h)(2)(iii ) of this section), to the extent necessary to protect them In the event of a spill or leak of a hazardous chemical from a sealed container".
Page 11 - For purposes of this section — (1) "construction" includes construction of new buildings, acquisition of existing buildings, and expansion, remodeling, alteration, and renovation of existing buildings, and initial equipment of such new, newly acquired, expanded, remodeled, altered, or renovated buildings; (2) the "cost" of construction includes the cost of architects...