NBS Minimal BASIC Test Programs: Version 2, User's Manual, Volume 13U.S. Department of Commerce, National Bureau of Standards, 1980 |
From inside the book
Results 11-15 of 69
Page 37
... control which element of the array gets the value . Also , it is here ( and only here ) that the standard's requirement for checking the input - reply before assignment is tested . Your first reply to this section of the test must cause ...
... control which element of the array gets the value . Also , it is here ( and only here ) that the standard's requirement for checking the input - reply before assignment is tested . Your first reply to this section of the test must cause ...
Page 47
... control statements , the diagnostics are rather sparse for failures . Check Volume 2 for an example of correct output . 5.14.3 Exceptions In Subscripts And Arguments The exceptions specified in section 7 and 8 apply to numeric ...
... control statements , the diagnostics are rather sparse for failures . Check Volume 2 for an example of correct output . 5.14.3 Exceptions In Subscripts And Arguments The exceptions specified in section 7 and 8 apply to numeric ...
Page 51
... Control Statements and REM 15-21 ( 10,18 ) 4.1 REM and GOTO 15-16 ( 10,18 ) 4.2 GOSUB and RETURN 17 ( 10 ) 4.3 IF - THEN 18-21 ( 10 ) ... 22-23 ( 6 ) 5 Variables 6 Numeric Constants , Variables , and Operations .24-43 ( 5,6,7 ) 6.1 ...
... Control Statements and REM 15-21 ( 10,18 ) 4.1 REM and GOTO 15-16 ( 10,18 ) 4.2 GOSUB and RETURN 17 ( 10 ) 4.3 IF - THEN 18-21 ( 10 ) ... 22-23 ( 6 ) 5 Variables 6 Numeric Constants , Variables , and Operations .24-43 ( 5,6,7 ) 6.1 ...
Page 52
... Control Statements 9.1 GOSUB and RETURN 9.2 ON - GOTO 10 READ , DATA , and RESTORE 10.1 Standard Capabilities 10.2 Exceptions 10.3 Errors 11 INPUT 11 . 1 Standard Capabilities 11.2 Exceptions 11.3 Errors 12 12.1 Program Number ANSI ...
... Control Statements 9.1 GOSUB and RETURN 9.2 ON - GOTO 10 READ , DATA , and RESTORE 10.1 Standard Capabilities 10.2 Exceptions 10.3 Errors 11 INPUT 11 . 1 Standard Capabilities 11.2 Exceptions 11.3 Errors 12 12.1 Program Number ANSI ...
Page 57
... CONTROL - VARIABLE WITHIN A FOR - BLOCK . REFS : 11.2 11.4 PROGRAM NUMBER 46 INTERACTION OF CONTROL STATEMENTS WITH THE FOR - STATEMENT . REFS : 11.2 11.4 10.2 10.4 PROGRAM NUMBER 47 INCREMENT IN THE STEP CLAUSE OF THE FOR - STATEMENT ...
... CONTROL - VARIABLE WITHIN A FOR - BLOCK . REFS : 11.2 11.4 PROGRAM NUMBER 46 INTERACTION OF CONTROL STATEMENTS WITH THE FOR - STATEMENT . REFS : 11.2 11.4 10.2 10.4 PROGRAM NUMBER 47 INCREMENT IN THE STEP CLAUSE OF THE FOR - STATEMENT ...
Other editions - View all
Common terms and phrases
15 PRINT 20 PRINT 40 PRINT SECTION ACCEPT THE PROGRAM ACCOMPANIED BY DOCUMENTATION ACCURATELY DESCRIBING ANSI STANDARD 7.2 APPROPRIATE ERROR MESSAGE ARGUMENT ASSIGNED BASIC TEST PROGRAMS COMPUTED DATA DESCRIBING THE FEATURE'S DETAILED CRITERIA DIM-STATEMENT DISPLAYED DIVISION BY ZERO END END TEST END PROGRAM FILE EXRAD FEATURE OF MINIMAL FEATURE'S INTERPRETATION FOR-STATEMENT GOSUB GOTO IDENTIFYING THE EXCEPTION implementation INFORMATIVE TEST PASSED INPUT INPUT-REPLY LINE NUMBER LINE-NUMBERS MACHINE INFINITY MESSAGE IDENTIFYING MINIMAL BASIC TEST NBS MINIMAL BASIC NON-STANDARD FEATURE NUMERIC EXPRESSIONS OK OK OK ON-GOTO OPTION BASE PASS THIS TEST PRINT 40 PRINT PRINT BEGIN TEST PRINT END PROGRAM PRINT END TEST PRINT FOR DETAILED PRINT PROGRAM FILE PRINT THIS PROGRAM PRINT THIS SECTION PRINT TO PASS PROCESSOR PROGRAM TESTS PROGRAMS USER'S MANUAL QUOTED STRINGS READ REFS REJECT THE PROGRAM REM SUBROUTINE RND FUNCTION SECTION TESTS SIGNIFICAND STATEMENT TEST IS INFORMATIVE TEST OK TEST PROGRAMS USER'S UNDERFLOW USER-DEFINED FUNCTION