Greater Wenatchee Division, Chief Joseph Dam Project, Washington. Letter... Pursuant to Section 9 (a) of the Reclamation Project Act of 1939 (53 Stat. 1187) and the Act of July 17, 1952 (66 Stat. 753)U.S. Government Printing Office, 1958 - 117 pages |
From inside the book
Results 1-5 of 24
Page vi
... distribution system . The total cost of the 4 units recommended for authorization is estimated as $ 9,734,800 based on October 1956 price levels , all of which is allocated to irrigation except about $ 85,000 which is proposed as a ...
... distribution system . The total cost of the 4 units recommended for authorization is estimated as $ 9,734,800 based on October 1956 price levels , all of which is allocated to irrigation except about $ 85,000 which is proposed as a ...
Page vii
... systems . All land would be irrigated by pumping from the Columbia River . Under each of the seven units making up the ... distribution system . Authorization at this time is recommended for only 4 of the 7 units . These units — Howard ...
... systems . All land would be irrigated by pumping from the Columbia River . Under each of the seven units making up the ... distribution system . Authorization at this time is recommended for only 4 of the 7 units . These units — Howard ...
Page ix
... systems . There are 10,852 acres of irrigable land in the 7 units , of which 9,357 acres are not now irrigated . All ... distribution system . The regional director recommends authorization at this time for only 4 of the 7 units . These ...
... systems . There are 10,852 acres of irrigable land in the 7 units , of which 9,357 acres are not now irrigated . All ... distribution system . The regional director recommends authorization at this time for only 4 of the 7 units . These ...
Page xxii
... Distribution system.Lateral system . North relift pumping plant . East relift pumping plant.Regulating reservoirs .. Construction and operation - Construction schedule.Operation and maintenance-Project costs .-Construction costs ...
... Distribution system.Lateral system . North relift pumping plant . East relift pumping plant.Regulating reservoirs .. Construction and operation - Construction schedule.Operation and maintenance-Project costs .-Construction costs ...
Page xxiii
... Distribution system . Lateral system . Relift pumping plant . Regulating reservoirs . Construction and operation .-- . Construction schedule .---Operation and maintenance . Project costs ... Construction costs .. Capitalized operating ...
... Distribution system . Lateral system . Relift pumping plant . Regulating reservoirs . Construction and operation .-- . Construction schedule .---Operation and maintenance . Project costs ... Construction costs .. Capitalized operating ...
Common terms and phrases
50-year period acres allocation alternative amount annual cost annual operating costs Antoine Creek unit apple authorization average basis budgets capacity capitalized operating costs charge Chelan Chief Joseph Dam Class Columbia River construction costs County crops Department designed discharge line distribution system East unit Electric estimated expenses facilities Federal feet fish and wildlife fish screens Foster Creek division fruit Greater Wenatchee division increased farm interest Interior investment irrigable acres irrigable land irrigation benefits Joseph Dam project July lateral system less located major Moses Coulee unit North Pateros unit Operation and maintenance orchard percent period pipe Plan of development present production proposed Public pumping plant Reclamation recommended region regulating reservoir repayment replacement Secretary selected serve shown South Pateros sprinkler steel summary supply TABLE terraces tion Total Wash Washington water users
Popular passages
Page 1 - Interior* under said plans shall be governed by the Federal Reclamation Laws (Act of June 17, 1902, 32 Stat. 388, and Acts amendatory thereof or supplementary thereto...
Page xi - I recommend further that you approve and adopt this report as your proposed report on the Greater Wenatchee division of the Chief Joseph Dam project, and that you authorize me, in your behalf, to transmit copies to the States of the Columbia River Basin and to the Secretary of the Army in accordance with requirements of the Flood Control Act of 1944 (58 Stat.
Page xi - State wherein the impoundment, diversion, or other control facility is to be constructed...
Page i - Interior, the proposed works shall not be deemed authorized except upon approval by an Act of Congress ; and subsection 9 (a) of the Reclamation Project Act of 1939 (53 Stat. 1187) and subsection 3 (a) of the Act of August 11, 1939 (53 Stat. 1418), as amended, are hereby amended accordingly.
Page iii - Hon. SAM RAYBURN, Speaker of the House of Representatives, Washington, DC DEAR MR. SPEAKER...
Page vii - Army in accordance with the provisions of section 1 (c) of the Flood Control Act of 1944 (58 Stat. 887) and to the State of...
Page ix - The SECRETARY OF THE INTERIOR. SIR: This is my proposed report on the initial development, Roaring Fork diversion, of the potential Gunnison-Arkansas project, Colorado.
Page 78 - Secretary determines to be beyond the ability of the water users to pay shall be charged to, and returnable to the reclamation fund from, net revenues derived from the sale of power from the...
Page xi - State, in accordance with provisions of the Act of August 14, 1946 (60 Stat.
Page 98 - Creek development as, upon further study in accordance with section 2 of the Act of August 14, 1946 (60 Stat. 1080, 16 USC 662), he finds to be required for the preservation and propagation of fish and wildlife.