NBS Special Publication, Issue 250U.S. Government Printing Office, 1965 |
From inside the book
Results 1-5 of 11
Page
... bolometer units and bolometer - coupler units ... 201.822 Pulse power , peak measurement , coaxial systems_ 201.830.
... bolometer units and bolometer - coupler units ... 201.822 Pulse power , peak measurement , coaxial systems_ 201.830.
Page
... bolometer units and bolometer - coupler units_ 201.911 Waveguide dry calorimeters _ _ 201.920 Waveguide reflectors ( mismatches ) . 201.930 Cavity wavemeters ... – 201.940 Attenuation difference , variable attenuators .. 201.941 ...
... bolometer units and bolometer - coupler units_ 201.911 Waveguide dry calorimeters _ _ 201.920 Waveguide reflectors ( mismatches ) . 201.930 Cavity wavemeters ... – 201.940 Attenuation difference , variable attenuators .. 201.941 ...
Page
... bolometer units and bolometer - coupler units 1.822 Pulse , peak power measurement , coaxial systems 1.830 Immittance , 30 kHz ( kc / s ) to 4 GHz ( Gc / s ) 1.840 Dissipative fixed coaxial attenuators 1.841 Dissipative variable coaxial ...
... bolometer units and bolometer - coupler units 1.822 Pulse , peak power measurement , coaxial systems 1.830 Immittance , 30 kHz ( kc / s ) to 4 GHz ( Gc / s ) 1.840 Dissipative fixed coaxial attenuators 1.841 Dissipative variable coaxial ...
Page 12
... bolometer units and bolometer - coupler units 201.822 Pulse , peak power measurement , coaxial systems 201.830 Immittance , 30 kHz ( kc / s ) to 4 GHz ( Gc / s ) 201.840 Dissipative fixed coaxial attenuators 201.841 Dissipative variable ...
... bolometer units and bolometer - coupler units 201.822 Pulse , peak power measurement , coaxial systems 201.830 Immittance , 30 kHz ( kc / s ) to 4 GHz ( Gc / s ) 201.840 Dissipative fixed coaxial attenuators 201.841 Dissipative variable ...
Page 36
... bolometer units and bolometer - coupler units . ( a ) A bolometer unit includes both the bolometer element or elements and the bolometer mount in which they are supported . ( b ) Power measurements are made on barretter - type bolometer ...
... bolometer units and bolometer - coupler units . ( a ) A bolometer unit includes both the bolometer element or elements and the bolometer mount in which they are supported . ( b ) Power measurements are made on barretter - type bolometer ...
Other editions - View all
Common terms and phrases
Ac-dc accepted for calibration accuracy additional American Standards Association API Standard apparatus Appendix attenuators bolometer bolometer units bulb and liquid Bureau of Standards calibration or test changes in emf charged dependent color temperature condenser microphones current fees decibels Determination diameter Electric electrode electromotive force end of table errors exceeding footnote at end frequency Gage blocks gages-determination glass Group of Standard higher or lower hygrometers ice-point reading indications inductors instruments Invar Item Description Fee laboratory length liquid column mass measurements meter National Reference Group ohms perature phase angle plug Precision pressure Radium ratio reference standards REPORT OF CALIBRATION resistance thermometer resistors ring gages sample saturated standard cells schedule special tests specifications spectrophotometer stability standard resistors submitted for calibration tabulated corrections apply temperature range test points test_ tests not covered thermal conductivity thermocouple thermometer was tested U.S. DEPARTMENT uncertainty voltage dividers waveguide weights
Popular passages
Page 11 - Standard Reference Materials issued by the National Bureau of Standards to calibrate a measurement system, or to produce scientific data that can be referred to a common base. A schedule of prices and amounts, as well as directions for ordering, is included.
Page 49 - ... index markers. Since it is necessary to determine the shift of the principal point resulting from prism effect in the lens, the equivalent focal length of the lens as mounted In the camera is incidentally determined...
Page 55 - ... wire loops, spring balances, tension handles, or other attachments liable to be detached or changed in shape. The error in the total length of the tape, when supported horizontally throughout its length at the standard temperature of 68° F. (20° C.) and at standard tension, shall not be more than 0.1 inch per 100 feet (2 mm per 25 m).