Aviation Safety: Issues Raised by the Crash of Valujet Flight 592 : Hearing Before the Subcommittee on Aviation of the Committee on Transportation and Infrastructure, House of Representatives, One Hundred Fourth Congress, Second Session, June 25, 1996U.S. Government Printing Office, 1997 - 571 pages |
From inside the book
Results 1-5 of 52
Page 11
... door , and he was calling out for retraining for a long time and did not receive it . A critical challenge that faces the FAA is the effective use of its limited assets . We all can recognize the FAA is never going to be in a position ...
... door , and he was calling out for retraining for a long time and did not receive it . A critical challenge that faces the FAA is the effective use of its limited assets . We all can recognize the FAA is never going to be in a position ...
Page 15
... doors , to 545 million passengers last year , a fivefold increase , the fatal accident rate has dropped , at the same time , almost 75 percent . Mr. Chairman , in 1995 , just last year , for example , there was one fatal Part 121 ...
... doors , to 545 million passengers last year , a fivefold increase , the fatal accident rate has dropped , at the same time , almost 75 percent . Mr. Chairman , in 1995 , just last year , for example , there was one fatal Part 121 ...
Page 39
... door seal on N934VV , a DC - 9-32 , when the seal was ruptureč . [ TTEM 191 N914VJ : An FAA inspector found the flap follow up cables mis - routed in the left wheel well . [ ITEM 20 ) N902VJ . May 26 , 1936 : DRAFT An N check follow ...
... door seal on N934VV , a DC - 9-32 , when the seal was ruptureč . [ TTEM 191 N914VJ : An FAA inspector found the flap follow up cables mis - routed in the left wheel well . [ ITEM 20 ) N902VJ . May 26 , 1936 : DRAFT An N check follow ...
Page 41
... door . [ ITEM 25 ] N923VV : Ar . FAA inspector observed that : The left wheel well flap follow - up cables were misrouted . 2 . There were improper fire extinguishers installed in the aft Lavatory . Valuje was unable to provide ...
... door . [ ITEM 25 ] N923VV : Ar . FAA inspector observed that : The left wheel well flap follow - up cables were misrouted . 2 . There were improper fire extinguishers installed in the aft Lavatory . Valuje was unable to provide ...
Page 72
... door's gust lock . The aircraft was subsequently returned to service without conclusive documentation that this non - deferrable discrepancy had been corrected . 8. On or about May 11 , 1996 , an inspection of the training and ...
... door's gust lock . The aircraft was subsequently returned to service without conclusive documentation that this non - deferrable discrepancy had been corrected . 8. On or about May 11 , 1996 , an inspection of the training and ...
Other editions - View all
Common terms and phrases
action Administrator agency Agreement aircraft airplane airworthiness airworthiness directives Atlanta aviation safety BACHUS BRODERICK canisters cargo certification Chairman check was accomplished compliance concerns consent order contractors crash crew DEFAZIO discrepancies were noted discretionary function exception documents door DUNCAN employees engine FAA inspectors FAA's Federal Aviation Federal Aviation Administration Federal Aviation Regulations FINDING firing pin flight attendant flying FOLD following discrepancies FSDO hazardous materials hearing heat shield HINSON industry insert unit inspection installed investigation issues JORDAN June 25 latch LIPINSKI low-cost carriers maintenance manual mechanics MENENDEZ NTSB OBERSTAR Office operations oversight oxygen mask oxygen module passengers performed personnel pilots pin lanyards problems procedures question Ramp check recommendations record regulations regulatory release removed repair stations responsibility S.Ct SabreTech SCHIAVO Secretary SELLER SHUSTER specific standards statement Subcommittee Thank ValuJet Airlines ValuJet Flight 592
Popular passages
Page 553 - Any claim based upon an act or omission of an employee of the Government, exercising due care, in the execution of a statute or regulation, whether or not such statute or regulation be valid, or based upon the exercise or performance or the failure to exercise or perform a discretionary function or duty on the part of a federal agency or an employee of the Government, whether or not the discretion involved be abused.
Page 553 - Authority, the periods for, and the manner in, which such inspection, servicing, and overhaul shall be made, including provision for examinations and reports by properly qualified private persons whose examinations or reports the Authority may accept in lieu of those made by its officers and employees...
Page 567 - The syllabus constitutes no part of the opinion of the Court but has been prepared by the Reporter of Decisions for the convenience of the reader. See United States v. Detroit Timber & Lumber Co., 200 US 321, 337. SUPREME COURT OF THE UNITED STATES Syllabus SAUCIER v.
Page 561 - Congress wished to prevent judicial "second-guessing" of legislative and administrative decisions grounded in social, economic, and political policy through the medium of an action in tort.
Page 554 - MR. CHIEF JUSTICE BURGER delivered the opinion of the Court. We granted certiorari...