Performance of Louvered Devices as Air MixersU.S. National Bureau of Standards, 1970 - 20 pages As part of a study evaluating methods for reducing thermal gradients within the cross section of an air stream, three louvered mixing devices were investigated. Each of these devices was found to be capable of reducing the cross-sectional nonuniformity of air temperature to a few percent of the entering value. |
From inside the book
Results 1-4 of 4
Page
... cents . BSS3 . Doors as Barriers to Fire and Smoke . 15 cents . BSS4 . Weather Resistance of Porcelain Enamels : Effect of Exposure Site and Other Variables After Seven Years . 20 cents BSS5 . Interrelations Between Cement and Concrete ...
... cents . BSS3 . Doors as Barriers to Fire and Smoke . 15 cents . BSS4 . Weather Resistance of Porcelain Enamels : Effect of Exposure Site and Other Variables After Seven Years . 20 cents BSS5 . Interrelations Between Cement and Concrete ...
Page
... For sale by the Superintendent of Documents , U.S. Government Printing Office Washington , D.C. 20402. ( Order by SD Catalog No. C 13.29 / 2 : 27 ) . Price , 30 cents 1. Introduction Contents Page 1 2. Apparatus and test procedure.
... For sale by the Superintendent of Documents , U.S. Government Printing Office Washington , D.C. 20402. ( Order by SD Catalog No. C 13.29 / 2 : 27 ) . Price , 30 cents 1. Introduction Contents Page 1 2. Apparatus and test procedure.
Page 4
... cent area the deflection of the air was to the right . The air streams issuing through adja- cent louvered strips moved in opposing direc- tions , thus creating a shearing action between the streams at their interface . Both the forces ...
... cent area the deflection of the air was to the right . The air streams issuing through adja- cent louvered strips moved in opposing direc- tions , thus creating a shearing action between the streams at their interface . Both the forces ...
Page 7
... cent as the spacing was increased from 0.5 to 1.5 duct diameters ; it remained constant at spacings greater than 1.5 duct diameters . Figure 9 presents the effectiveness as a func- tion of overall distance between the first mixer ...
... cent as the spacing was increased from 0.5 to 1.5 duct diameters ; it remained constant at spacings greater than 1.5 duct diameters . Figure 9 presents the effectiveness as a func- tion of overall distance between the first mixer ...
Common terms and phrases
0.92 duct diameter 4.75 DUCT DIAMETERS air flow Air Mixers air passed AIR STREAM VELOCITY apparatus ASHRAE automatic data processing baffles blower Building Science Series Bureau of Standards cents circular band concentric louver mixing CONCENTRIC TEMPERATURE PATTERN cross section deg F Devices as Air DIAMETER DUCT FPM DIAMETERS MEAN VELOCITY direct the air DISTANCE BETWEEN MIXING downstream measuring station Duct Diam DUCT DIAMETERS MEAN duct wall elements in series evaluated FIGURE 17 flow rate held constant louver angle louver mixing device LOUVER SETTING louver-baffle mixing device louvered strip mixing MEAN AIR STREAM ment metal mixing effectiveness National Bureau normal path outer area path of flow PATTERN THREE QUADRANTS percent pitot-static tubes QUADRANT COOL QUADRANT TEMPERATURE PATTERN Resistance Thermometer shown in figure spacing between mixing standard deviation strip mixer strip mixing device tempera temperature difference TEMPERATURE PATTERN THREE test conditions THERMOCOUPLES THREE QUADRANTS WARM tion ture U.S. Government Printing velocity head
Popular passages
Page 1 - A schematic of the apparatus is shown in figure 1. Figure 2 is a photograph of the apparatus.
Page 20 - Announcement of New Publications in Building Science Series Superintendent of Documents, US Government Printing Office, Washington, DC 20402 Dear Sir: Please add my name to the announcement list of new publications to be issued in the series : National Bureau of Standards Building Science Series. Name Company Address City State Zip Code (Notification key N-339...