| 2005 - 840 pages
...partial pressure exerted by a petroleum liquid as determined in accordance with methods described ir. American Petroleum Institute Bulletin 2517. Evaporation...disposal system capable of processing such hydrocarbon vapor.and gases so as to prevent their emission to the atmosphere. (1) Reid vapor pressure is the absolute... | |
| 1997 - 1214 pages
...Floating-Roof Tanks, Second Edition February 1980 (incorporated by reference — see §60.17). (}) Floating roof means a storage vessel cover consisting...disposal system capable of processing such hydrocarbon vapore and gases so as to prevent their emission to the atmosphere. 0) Reid vapor pressure is the absolute... | |
| 2000 - 810 pages
...consisting of a double deck or pontoon single deck which rests upon and is supported by the volatile organic liquid being contained and is equipped with a closure...to close the space between the roof edge and tank shell. Extreme environmental conditions means exposure to any or all of the following: ambient weather... | |
| 2000 - 946 pages
...single deck, internal floating cover or covered floating roof, which rests upon and is supported by the liquid being contained, and is equipped with a closure...seals to close the space between the roof edge and waste management unit or storage tank wall. Flow indicator means a device which indicates whether gas... | |
| 1999 - 1298 pages
...single deck, internal floating cover or covered floating roof, which rests upon and is supported by the liquid being contained, and is equipped with a closure...seals to close the space between the roof edge and waste management unit or storage tank wall. Flow indicator means a device which indicates whether gas... | |
| 1993 - 908 pages
...floating cover or covered floating roof, which rests upon and is supported by the liquid being COEtained. and is equipped with a closure seal or seals to close the space between the roof edge and unit wall. Flow indicator means a device which indicates whether gas flow is present is a line or vent... | |
| 1976 - 880 pages
...consisting of a pontoon type or double deck type roof, reeting on the surface of the liquid contents and equipped with a closure seal, or seals, to close the space between the roof edge and tank wall. The control equipment provided for in this paragraph shall not be used If the gasoline or petroleum... | |
| 1974 - 1028 pages
...consisting of a pontoon type or double deck type roof, resting on the surface of the liquid contents and equipped with a closure seal, or seals, to close the space between the roof edge and tank wall. The control equipment provided for in this paragraph shall not be used if the gasoline or petroleum... | |
| 1966 - 698 pages
...pontoon-type or double-deck-type roof, which will rest on the surface of the liquid contents and be equipped with a closure seal, or seals, to close the space between the roof edge and tank wall. The control equipment to be provided for in this subsection B (1) shall not be permitted if the gasoline... | |
| United States. Congress. Senate. Committee on Public Works - 1967 - 1140 pages
...consisting of a pontoon type or double-deck type roof, resting on the surface of the liquid contents and equipped with a closure seal, or seals, to close the space between the roof edge and tank wall. The control equipment provided for in this paragraph shall not be used if the gasoline or petroleum... | |
| |