The Code of Federal Regulations of the United States of AmericaU.S. Government Printing Office, 1999 The Code of Federal Regulations is the codification of the general and permanent rules published in the Federal Register by the executive departments and agencies of the Federal Government. |
From inside the book
Results 1-5 of 100
Page 5
... Solid Waste Landfills 60.30c Scope . 60.31c Definitions . 60.32c Designated facilities . 60.33c Emission guidelines for municipal solid waste landfill emissions . 60.34c Test methods and procedures . 60.35c Reporting and recordkeeping ...
... Solid Waste Landfills 60.30c Scope . 60.31c Definitions . 60.32c Designated facilities . 60.33c Emission guidelines for municipal solid waste landfill emissions . 60.34c Test methods and procedures . 60.35c Reporting and recordkeeping ...
Page 14
... Solid Waste Landfills 60.750 Applicability , designation of affected facility , and delegation of authority . Definitions . 60.751 60.752 Standards for air emissions from mu- nicipal solid waste landfills . 60.753 Operational standards ...
... Solid Waste Landfills 60.750 Applicability , designation of affected facility , and delegation of authority . Definitions . 60.751 60.752 Standards for air emissions from mu- nicipal solid waste landfills . 60.753 Operational standards ...
Page 51
... solid waste landfills 4 1 Low numbers have highest priority , e.g. , No. 1 is high pri- onty , No. 59 is low priority . 2 Formerly titled " Sintering : Clay and Fly Ash " . 3Minor source category , but included on list since an NSPS is ...
... solid waste landfills 4 1 Low numbers have highest priority , e.g. , No. 1 is high pri- onty , No. 59 is low priority . 2 Formerly titled " Sintering : Clay and Fly Ash " . 3Minor source category , but included on list since an NSPS is ...
Page 64
... solid waste for which construction was commenced on or before September 20 , 1994 . ( b ) Any municipal waste combustion unit that is capable of combusting more than 250 tons per day of munic- ipal solid waste and is subject to a fed ...
... solid waste for which construction was commenced on or before September 20 , 1994 . ( b ) Any municipal waste combustion unit that is capable of combusting more than 250 tons per day of munic- ipal solid waste and is subject to a fed ...
Page 65
... solid waste combusted at the cofired combustor and the weight of all other fuels combusted at the cofired com- bustor . ( j ) Air curtain incinerators , as de- fined under § 60.51b of subpart Eb of this part , that meet the capacity ...
... solid waste combusted at the cofired combustor and the weight of all other fuels combusted at the cofired com- bustor . ( j ) Air curtain incinerators , as de- fined under § 60.51b of subpart Eb of this part , that meet the capacity ...
Other editions - View all
Common terms and phrases
acid Administrator affected facility Applicability and designation approved atmosphere average calculated calibration carbon cility coating operation coating solids combustion comply concentration control device deter determined dry basis emis emission limit emission rate equipment erator fected following equation formance fuel furnace gas stream gases heat input incinerator initial performance test install kilograms landfill liquid mass of VOC means measured megagrams ment methods and procedures monitoring device monitoring system municipal solid waste municipal waste municipal waste combustor nitrogen oxides opacity operator subject owner or operator oxides emission oxygen particulate matter percent performance test required period pitot tube plant port pressure probe provisions record reduction Reference Method sampling sions solid waste solvent stack or duct steam generating unit subpart sulfur dioxide temperature Test methods tion traverse point velocity vent stream VOC emissions volume volumetric flow rate wind tunnel yaw angle
Popular passages
Page 58 - standard of performance" means a standard for emissions of air pollutants which reflects the degree of emission limitation achievable through the application of the best system of emission reduction which (taking into account the cost of achieving such reduction) the Administrator determines has been adequately demonstrated.
Page 377 - fixed capital cost of the new components" includes the fixed capital cost of all depreciable components (except components specified in §60.506(a)) which are or will be replaced pursuant to all continuous programs of component replacement which are commenced within any 2year period following December 17, 1980. For purposes of this paragraph, "commenced...
Page 566 - solid waste" means any garbage, refuse, sludge from a waste treatment plant, water supply treatment plant, or air pollution control facility and other discarded material, including solid, liquid, semisolid, or contained gaseous material resulting from industrial, commercial, mining, and agricultural operations, and from community activities, but does not include solid or dissolved material in domestic sewage, or solid or dissolved materials in irrigation return, flows or industrial discharges which...
Page 16 - Electric utility steam generating unit means any steam electric generating unit that is constructed for the purpose of supplying more than onethird of its potential electric output capacity and more than 25 MW electrical output to any utility power distribution system for sale. Any steam supplied to a steam distribution...
Page 445 - Petroleum means the crude oil removed from the earth and the oils derived from tar sands, shale, and coal. Petroleum refinery means any facility engaged in producing gasoline, kerosene, distillate fuel oils, residual fuel oils, lubricants, or other products through the distillation of petroleum, or through the redistillation, cracking, or reforming of unfinished petroleum derivatives.
Page 353 - Process unit means components assembled to produce, as intermediate or final products, one or more of the chemicals listed in §60.489 of this part. A process unit can operate independently if supplied with sufficient feed or raw materials and sufficient storage facilities for the product. Process unit shutdown...
Page 524 - For purposes of this paragraph, "commenced" means that an owner or operator has undertaken a continuous program of component replacement or that an owner or operator has entered into a contractual obligation to undertake and complete, within a reasonable time, a continuous program of component replacement.
Page 374 - Continuous vapor processing system" means a vapor processing system that treats total organic compounds vapors collected from gasoline tank trucks on a demand basis without intermediate accumulation in a vapor holder. "Existing vapor processing system" means a vapor processing system [capable of achieving emissions to the atmosphere no greater than 80 milligrams of total organic compounds per liter of gasoline loaded], the construction or refurbishment of which was commenced before December 17, 1980,...
Page 215 - A floating roof, consisting of a pontoon type or double deck type roof, resting on the surface of the liquid contents and equipped with a closure seal, or seals, to close the space between the roof edge and tank wall. The control equipment...
Page 15 - Alternative method" means any method of sampling and analyzing for an air pollutant which is not a reference or equivalent method but which has been demonstrated to the Administrator's satisfaction to, in specific cases, produce results adequate for his determination of compliance. "Capital expenditure...