NBS Voluntary Product StandardU.S. Department of Commerce, National Bureau of Standards, 1972 |
From inside the book
Page 3
... tested in accordance with 4.4 . 3.5 . Specific gravity - The tubing shall have a specific gravity as specified in table 3 when tested in accordance with 4.5 . 3.6 . Tensile strength and elongation - The tubing shall have a tensile ...
... tested in accordance with 4.4 . 3.5 . Specific gravity - The tubing shall have a specific gravity as specified in table 3 when tested in accordance with 4.5 . 3.6 . Tensile strength and elongation - The tubing shall have a tensile ...
Page 4
... tested in accordance with 4.9 . TABLE 4. Minimum dielectric breakdown voltage for Grade A , PTFE tubing Dielectric ... tested in accordance with 4.10 . 3.11 . Minimum proof pressure ( applicable only to Grade B tub- ing ) -The ...
... tested in accordance with 4.9 . TABLE 4. Minimum dielectric breakdown voltage for Grade A , PTFE tubing Dielectric ... tested in accordance with 4.10 . 3.11 . Minimum proof pressure ( applicable only to Grade B tub- ing ) -The ...
Page 5
... accordance with ASTM D 1675-65 , Standard Methods of Test- ing Electrical Grade Polytetrafluoroethylene Tubing.3 4.3.2 . Wall thickness - The wall thickness shall be determined in accordance with the procedures described in ASTM D 1675 ...
... accordance with ASTM D 1675-65 , Standard Methods of Test- ing Electrical Grade Polytetrafluoroethylene Tubing.3 4.3.2 . Wall thickness - The wall thickness shall be determined in accordance with the procedures described in ASTM D 1675 ...
Page 6
... tested as filaments . Nonslip type loop knots shall be made in each end of the specimen so that there are 1 % inches ... accordance with 4.3.1 . and 4.3.2 . Place the specimen on a steel mandrel having a diameter from 3 to 6 Tubing ...
... tested as filaments . Nonslip type loop knots shall be made in each end of the specimen so that there are 1 % inches ... accordance with 4.3.1 . and 4.3.2 . Place the specimen on a steel mandrel having a diameter from 3 to 6 Tubing ...
Page 7
... accordance with 4.3.1 and 4.3.2 . The percent change of any dimension shall not exceed that specified in table 3 ... test specimen shall be clamped off at one end and attached at the other end to a pressurizing device capable of ...
... accordance with 4.3.1 and 4.3.2 . The percent change of any dimension shall not exceed that specified in table 3 ... test specimen shall be clamped off at one end and attached at the other end to a pressurizing device capable of ...
Common terms and phrases
accordance with ASTM Almac Plastics American Hospital Association automatic data processing Breden Bunnel Plastics Bureau of Standards Calif Camden Chemical Company Chemplast Chicago compliance conforming Department of Commerce determined in accordance Development of Voluntary dielectric breakdown voltage Dimensions and tolerances direction in accordance effective date electrical Engineering Standards Services Fluorocarbon Government Hewlett Packard IBM Corporation identifying products Inch Inch Inch inclusive industry inside diameter less Institute intended for chemical Lake Shore Drive longitudinal LOOP KNOT mandrel methods of test Minimum proof pressure National Bureau November 15 Office of Engineering Ohio Philadelphia Pittsburgh Poughkeepsie Procedures producer or distributor Products Company provides technical psig PTFE tubing purchaser and seller requirements resin right to depart Roberts and Porter specific gravity specified in table Standard PS 52-71 Standard Reference strength and elongation Technology temperature tensile strength tested in accordance Transverse specimens tubing is intended U.S. Department Voluntary Product Standard Washington