NBS Special Publication, Issues 411-415U.S. Government Printing Office, 1974 |
From inside the book
Results 1-5 of 100
Page 132
... Particle Particle 193 227 1.83 26 2.21 48 ∞ 319 0.94 ( sec ) 323 board board Fir Gypsum 134 168 1.83 32 2.21 49 358 00 00 Plywood board Lauan Gypsum 148 168 1.83 19 2.21 44 317 ∞ ∞ Plywood board Gypsum Particle 192 ∞ 0.53 34 0 ...
... Particle Particle 193 227 1.83 26 2.21 48 ∞ 319 0.94 ( sec ) 323 board board Fir Gypsum 134 168 1.83 32 2.21 49 358 00 00 Plywood board Lauan Gypsum 148 168 1.83 19 2.21 44 317 ∞ ∞ Plywood board Gypsum Particle 192 ∞ 0.53 34 0 ...
Page 146
... particle board walls as shown in figure 6. The level of this flux is the main criterion for flash- over or full room ... particle board walls . Flashover did not occur for the full- scale lauan test and for only one of the model lauan ...
... particle board walls as shown in figure 6. The level of this flux is the main criterion for flash- over or full room ... particle board walls . Flashover did not occur for the full- scale lauan test and for only one of the model lauan ...
Page 176
... particle sizes were estimated as follows : Composition rigid PVC red oak ABS Estimated Maximum ( um ) Estimated Minimum ( μm ) 15 0.15 plasticized PVC 24 0.10 2 0.30 30 0.15 No attempt was made at this time to estimate particle size ...
... particle sizes were estimated as follows : Composition rigid PVC red oak ABS Estimated Maximum ( um ) Estimated Minimum ( μm ) 15 0.15 plasticized PVC 24 0.10 2 0.30 30 0.15 No attempt was made at this time to estimate particle size ...
Page 179
... particle sizes were estimated as follows : Composition rigid PVC red oak ABS Estimated Maximum ( μm ) Estimated Minimum ( um ) 15 0.15 plasticized PVC 24 0.10 2 0.30 30 0.15 No attempt was made at this time to estimate particle size ...
... particle sizes were estimated as follows : Composition rigid PVC red oak ABS Estimated Maximum ( μm ) Estimated Minimum ( um ) 15 0.15 plasticized PVC 24 0.10 2 0.30 30 0.15 No attempt was made at this time to estimate particle size ...
Page 179
... particle sizes were estimated as follows : Composition rigid PVC Estimated Maximum ( μm ) Estimated Minimum ( um ) 15 0.15 plasticized PVC red oak ABS 24 0.10 2 0.30 30 0.15 No attempt was made at this time to estimate particle size ...
... particle sizes were estimated as follows : Composition rigid PVC Estimated Maximum ( μm ) Estimated Minimum ( um ) 15 0.15 plasticized PVC red oak ABS 24 0.10 2 0.30 30 0.15 No attempt was made at this time to estimate particle size ...
Contents
5 | |
20 | |
37 | |
50 | |
59 | |
90 | |
103 | |
125 | |
139 | |
154 | |
165 | |
178 | |
195 | |
201 | |
215 | |
230 | |
237 | |
1 | |
13 | |
21 | |
33 | |
41 | |
57 | |
65 | |
49 | |
50 | |
55 | |
55 | |
vi | |
13 | |
19 | |
37 | |
45 | |
55 | |
63 | |
75 | |
83 | |
91 | |
Other editions - View all
Common terms and phrases
aerosol sprays analysis analyzer antiperspirant Applications atomic beam Building Bureau of Standards burn room calibration calorimeter Capability carbon monoxide carpet ceiling cellulose char length chemical Chemistry combustion concentration Contact corridor cotton crib density detector determine diameter distribution droplet effect electrical electron energy Engineering fabric facility fire department fire investigation Fire Research Fire Safety fire tests firefighters flame retardant flame spread flameover flammability flow frequency Gaithersburg gypsum board hazard heat ignition source inches instrument intensity involved isotopes laboratory laser light scattering Literature mass materials ment micrometer molecular National Bureau NBS Reactor neutron nylon operation optical optical density oxide oxygen particles percent phase Phone phosphorus polymer problems pyrolysis radiant flux radiation range sample Section smoke soffit specimen spectrometer spray structure studies surface Tech techniques Technology temperature test method thermal tion vertical wall