NBS Special Publication, Issues 411-415U.S. Government Printing Office, 1974 |
From inside the book
Results 1-5 of 100
Page ix
... chief can analyze the injuries his firefighters suffer . Based on this analysis , the Chief can decide how to modify his firefighting tactics , training , or equipment so as to reduce injuries . The Research : Research can provide ...
... chief can analyze the injuries his firefighters suffer . Based on this analysis , the Chief can decide how to modify his firefighting tactics , training , or equipment so as to reduce injuries . The Research : Research can provide ...
Page 181
... chief problem appears to be the failure of continuity of what could be an adequate protective sheath , there are some other areas of design construction and layout features which contribute to the extension of a typical confinable fire ...
... chief problem appears to be the failure of continuity of what could be an adequate protective sheath , there are some other areas of design construction and layout features which contribute to the extension of a typical confinable fire ...
Page 187
... chief problem appears to be the failure of continuity of what could be an adequate protective sheath , there are some other areas of design construction and layout features which contribute to the extension of a typical confinable fire ...
... chief problem appears to be the failure of continuity of what could be an adequate protective sheath , there are some other areas of design construction and layout features which contribute to the extension of a typical confinable fire ...
Page 187
... chief problem appears to be the failure of continuity of what could be an adequate protective sheath , there are some other areas of design construction and layout features which contribute to the extension of a typical confinable fire ...
... chief problem appears to be the failure of continuity of what could be an adequate protective sheath , there are some other areas of design construction and layout features which contribute to the extension of a typical confinable fire ...
Page
... stimulate the development of new methodology for making rapid and reliable aerosol measurements . Philip D. LaFleur , Acting Chief Analytical Chemistry Division PREFACE in This seminar was organized to provide provide an iv.
... stimulate the development of new methodology for making rapid and reliable aerosol measurements . Philip D. LaFleur , Acting Chief Analytical Chemistry Division PREFACE in This seminar was organized to provide provide an iv.
Contents
5 | |
20 | |
37 | |
50 | |
59 | |
90 | |
103 | |
125 | |
139 | |
154 | |
165 | |
178 | |
195 | |
201 | |
215 | |
230 | |
237 | |
1 | |
13 | |
21 | |
33 | |
41 | |
57 | |
65 | |
49 | |
50 | |
55 | |
55 | |
vi | |
13 | |
19 | |
37 | |
45 | |
55 | |
63 | |
75 | |
83 | |
91 | |
Other editions - View all
Common terms and phrases
aerosol sprays analysis analyzer antiperspirant Applications atomic beam Building Bureau of Standards burn room calibration calorimeter Capability carbon monoxide carpet ceiling cellulose char length chemical Chemistry combustion concentration Contact corridor cotton crib density detector determine diameter distribution droplet effect electrical electron energy Engineering fabric facility fire department fire investigation Fire Research Fire Safety fire tests firefighters flame retardant flame spread flameover flammability flow frequency Gaithersburg gypsum board hazard heat ignition source inches instrument intensity involved isotopes laboratory laser light scattering Literature mass materials ment micrometer molecular National Bureau NBS Reactor neutron nylon operation optical optical density oxide oxygen particles percent phase Phone phosphorus polymer problems pyrolysis radiant flux radiation range sample Section smoke soffit specimen spectrometer spray structure studies surface Tech techniques Technology temperature test method thermal tion vertical wall