From inside the book
Results 1-3 of 83
Page 131
... i.e. implicit problem solving routines Information ( data ) and control of the program are integrated Control structure is separated from the information ( knowledge ) base Correct answers are expected Often not completely exact ...
... i.e. implicit problem solving routines Information ( data ) and control of the program are integrated Control structure is separated from the information ( knowledge ) base Correct answers are expected Often not completely exact ...
Page 158
Power Line Structure Foundations structure with a mechanical or a welded connection . The number and size of anodes to be installed per structure are determined by the corrosion engineer based upon the surface area and condition ...
Power Line Structure Foundations structure with a mechanical or a welded connection . The number and size of anodes to be installed per structure are determined by the corrosion engineer based upon the surface area and condition ...
Page 158
Power Line Structure Foundations . structure with a mechanical or a welded connection . The number and size of anodes to be installed per structure are determined by the corrosion engineer based upon the surface area and condition ...
Power Line Structure Foundations . structure with a mechanical or a welded connection . The number and size of anodes to be installed per structure are determined by the corrosion engineer based upon the surface area and condition ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Other editions - View all
Common terms and phrases
acid activity addition alloy aluminum analysis anodic application base changes chemical cleaning coatings combination compared composition concentration conclusion considered containing copper corrosion Corrosion Control curve density deposits described determine direct effect electrochemical electron Engineering environment equipment evaluation example experimental expert system factor field Figure function given higher important increase industry inhibitor ions Israel knowledge layer less limited materials measurements mechanical metal method observed obtained operation organic oxide paint passivation performance plant plating polarization possible potential practical present problems properties protection Radioactive Tracer reduce reference reported resistance REVIEWS rules runs rust samples selection shown shows solution specific specimen stainless steel standard structure surface Table technique Technology temperature tube values welding