Investigation of Performance Characteristics for Sanitary Plumbing FixturesU.S. National Bureau of Standards, 1970 - 68 pages |
From inside the book
Results 1-5 of 30
Page
... Loads Applied to a Bearing Wall . 15 cents BSS15 . Interrelations Between Cement and Concrete Properties : Part 4 , Shrinkage of Hardened Port- land Cement Pastes . 75 cents BSS16 . Techniques for the Survey and Evaluation of Live Floor ...
... Loads Applied to a Bearing Wall . 15 cents BSS15 . Interrelations Between Cement and Concrete Properties : Part 4 , Shrinkage of Hardened Port- land Cement Pastes . 75 cents BSS16 . Techniques for the Survey and Evaluation of Live Floor ...
Page
... loading ( bathtub ) ( S101 ) . Concentrated load , static ( bathtub ) ( S102 ) Rim load ( bathtub ) ( S102A ) . Concentrated dynamic load ( bathtub ) ( S103 ) __ 2.5 . Concentrated load , sump sidewall ( bath- tub ) ( S104 ) . . 2.16 ...
... loading ( bathtub ) ( S101 ) . Concentrated load , static ( bathtub ) ( S102 ) Rim load ( bathtub ) ( S102A ) . Concentrated dynamic load ( bathtub ) ( S103 ) __ 2.5 . Concentrated load , sump sidewall ( bath- tub ) ( S104 ) . . 2.16 ...
Page 1
... load capacity ; cleanability and soilability . 1.1 Statement of the Problem 1. Introduction The recent introduction into the market of new sanitary plumbing fixture materials , such as re- inforced plastics , has emphasized the need for ...
... load capacity ; cleanability and soilability . 1.1 Statement of the Problem 1. Introduction The recent introduction into the market of new sanitary plumbing fixture materials , such as re- inforced plastics , has emphasized the need for ...
Page 4
... sume the responsibility for appropriate conver- sion to International Standard ( SI ) units . For example , 0.500 in equals 1.27 cm , 2.1 lb equals 0.95 kg , 120 ° F equals 48.9 ° C , etc. 2.1 . Uniform Loading ( Bathtub ) ( S101 ) 4.
... sume the responsibility for appropriate conver- sion to International Standard ( SI ) units . For example , 0.500 in equals 1.27 cm , 2.1 lb equals 0.95 kg , 120 ° F equals 48.9 ° C , etc. 2.1 . Uniform Loading ( Bathtub ) ( S101 ) 4.
Page 5
... load at the center of the sump 3 would usually be more severe than a uni- form load of 339 lbs . Therefore , if the recom- mended concentrated static - load test ( Sec . 2.2 ) is used a uniform - load test would not be needed . Although ...
... load at the center of the sump 3 would usually be more severe than a uni- form load of 339 lbs . Therefore , if the recom- mended concentrated static - load test ( Sec . 2.2 ) is used a uniform - load test would not be needed . Although ...
Common terms and phrases
abraded abrasion ammonium hydroxide apparatus ASTM designation blisters Bon Ami bottom brush Brush Brush Brush Bureau of Standards cast-iron center deflection cleanability cleaning color Comments on Performance Commercial Standard cracking cycles damage depth detergent dial gage diam Discussion of Existing drain enameled evaluate exposure fixture materials flat specimens FRPE bathtubs FRPE fixtures FRPE specimens gel-coat household chemicals inspection installed iron laboratory manufacturers Mercurochrome National Bureau observed percent Performance Level Performance Requirements plastic polyester porcelain proposed revision Purpose and Scope Rationale for Suggested Rationale for Test Recommended Test Method removal resistance rating sanitary plumbing fixtures sanitary ware Scope The purpose scouring powder scratch scratch test scrub section 2.8 simulate slip resistance slurry soap Sodium soilability soiling agent Spec stain rating Suggested Format sump surface TEFLON temperature test area Test Development test procedure Test Results Tester thermal shock tion vitreous china watch glass weight
Popular passages
Page 4 - In no case does such identification imply recommendation or endorsement by the National Bureau of Standards , nor does it imply that the...
Page 1 - This report gives findings and recommendations developed during an investigation of performance characteristics for sanitary plumbing fixtures, conducted at the request of the Building Research Advisory Board of the National Academy of Sciences-National Research Council. The...