" Kc, for bolometer-coupler units is defined as the ratio of the substituted dc power in the bolometer unit on the side arm of the directional coupler to the microwave power incident upon a non-reflecting load connected to the output port of the main arm. "
Special Publication - Page 5-7
1968
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

1964 - 806 pages
...incident upon the bolometer unit. (f) Calibration factor, K c , for bolometer-coupler units is denned as the ratio of the substituted dc power in the bolometer...microwave power incident upon a non-reflecting load connected to the output port of the main arm. Item 201.910al 201.910a-2 201.910bl 201.910b-2 201.910C-1...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

1960 - 474 pages
...mount-directional coupler combinations is defined as the ratio of the substituted dc power in the bolometer element on the side arm of the directional coupler to the...incident upon a nonreflecting load attached to the mainline port. § 201.902 Reflection coefficient magnitude measurement on waveguide reflectors (mismatches)....
Full view - About this book

The Code of Federal Regulations of the United States of America

1966 - 522 pages
...the substituted dc power in the bolometer unit on the side arm of the directional coupler to the rf power incident upon a nonreflecting load attached to the output port of the main arm.8 (h) For temperature-compensated bolometer units, the dc cable may be *See{201.800(b). Fees. 1...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

1965 - 526 pages
...bolometer unit to the microwave power incident upon the bolometer unit. (f ) Calibration factor, Kc, for bolometer-coupler units is defined as the ratio...microwave power incident upon a non-reflecting load connected to the output port of the main arm. Item 201.910al 201.910a-2 201.910bl 201.910D-2 201.910C-1...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

1966 - 562 pages
...the substituted dc power in the bolometer unit on the side arm of the directional coupler to the rf power incident upon a nonreflecting load attached to the output port of the main arm.8 (h) For temperature-compensated bolometer units, the dc cable may be •See § 201.800(b). Fees....
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

1967 - 660 pages
...the substituted dc power in the bolometer unit on the side arm of the directional coupler to the rf power incident upon a nonreflecting load attached to the output port of the main arm." (h) For temperature-compensated bolometer units, the dc cable may be •See § 201.800(b). Fees. 1...
Full view - About this book

The Code of Federal Regulations of the United States of America

1967 - 516 pages
...substituted dc power in the bolometer unit to the microwave power incident upon the bolometer unit. (f) Calibration factor for bolometercoupler units is defined...load attached to the output port of the main arm. (g) Effective efficiency for bolometer units is defined as the ratio of the substituted dc power in...
Full view - About this book

The Code of Federal Regulations of the United States of America

1964 - 584 pages
...WR28... unit to the microwave power incident upon the bolometer unit. (f ) Calibration factor, Kc, for bolometer-coupler units is defined as the ratio...microwave power incident upon a non-reflecting load connected to the output port of the main arm. Item 201.910al 201.910a-2 201.910bl 201.910b-2 201.910C-1...
Full view - About this book

The Code of Federal Regulations of the United States of America

1964 - 588 pages
...incident upon the bolometer unit. (f ) Calibration factor, K.,, for bolometer-coupler units is denned as the ratio of the substituted dc power in the bolometer...microwave power incident upon a non-reflecting load connected to the output port of the main arm. Item 201.910al 201.910a-2 201.910bl 201.910b-2 201.910C-1...
Full view - About this book

The Code of Federal Regulations of the United States of America

1967 - 524 pages
...the substituted dc power in the bolometer unit on the side arm of the directional coupler to the rf power incident upon a nonreflecting load attached to the output port of the main arm.8 (h) For temperature-compensated bolometer units, the dc cable may be *See { 201.800(b). Fees....