Special PublicationNational Bureau of Standards, 1968 |
From inside the book
Results 1-5 of 10
Page v
... Roundness 212.226.1 Roundness standards- 212.226.2 Roundness calibration specimens -- 212.226.3 Roundness measurements- 212.227 212.227.1 Surface texture Instrument calibration specimens 212.227.2 Surface roughness measurements- 212.228 ...
... Roundness 212.226.1 Roundness standards- 212.226.2 Roundness calibration specimens -- 212.226.3 Roundness measurements- 212.227 212.227.1 Surface texture Instrument calibration specimens 212.227.2 Surface roughness measurements- 212.228 ...
Page 3-22
... roundness to +0.000 05 inch for sizes up to and including 4 inches . Plain cylindrical plug gages - determination of diameter at a specific location , taper , and roundness to +0.000 010 inch for sizes up to and including 2 inches ...
... roundness to +0.000 05 inch for sizes up to and including 4 inches . Plain cylindrical plug gages - determination of diameter at a specific location , taper , and roundness to +0.000 010 inch for sizes up to and including 2 inches ...
Page 3-23
... roundness for each of two wires in a single set and reporting mean diameter within an uncertainty of +0.000 010 inch on label . See minimum fee under 212.220 ( c ) . Reference master wires - determining average diameter , taper , and ...
... roundness for each of two wires in a single set and reporting mean diameter within an uncertainty of +0.000 010 inch on label . See minimum fee under 212.220 ( c ) . Reference master wires - determining average diameter , taper , and ...
Page 3-24
... roundness on three equators . For sizes up to 1 inch in diameter . Measurements made only on balls with diameter ... roundness to ± 0.000 01 inch for sizes 0.035 inch up to and including 2 inches . 2.221.6b Plain cylindrical ring gages ...
... roundness on three equators . For sizes up to 1 inch in diameter . Measurements made only on balls with diameter ... roundness to ± 0.000 01 inch for sizes 0.035 inch up to and including 2 inches . 2.221.6b Plain cylindrical ring gages ...
Page 3-30
... roundness round parts , instrument calibration standards for roundness measurement ipment can be calibrated . 212.226.1 Roundness standards . The deviation from roundness at 8 or more specific positions und these nominally round ...
... roundness round parts , instrument calibration standards for roundness measurement ipment can be calibrated . 212.226.1 Roundness standards . The deviation from roundness at 8 or more specific positions und these nominally round ...
Other editions - View all
Common terms and phrases
accuracy actual costs additional attenuation Attenuation Range Autocollimating available:(a bolometer unit Bureau of Standards calibration or test calibrations not covered capacitance capacitors cavity wavemeter Coaxial coaxial connectors Determination dial Direct inquiries directional couplers Estimated Limits Exposure rate Frequency MHz Frequency Range gage blocks hydrometers inch insertion loss Instr Item Description laboratory length Limits of Uncertainty mark shipments measurements not covered meter method microwave National Bureau NBS Fee Schedule neutron noise temperature nonreflecting ohms percent phase angle Phase Shifters platinum plug and ring Powermeters pyrometers R. W. Beatty R/min ratio reflection coefficient reflection coefficient magnitude resistors ring gages sample scale Section setting signal sources Special calibrations Special measurements specified specimen standard attenuation submitted surface technique Telephone Thermal thermocouple thread Type N connectors uncertainty limits values of emf voltage dividers VSWR waveguide WWVB WWVH zero ει
Popular passages
Page 1-1 - THE INSTITUTE FOR BASIC STANDARDS provides the central basis within the United States of a complete and consistent system of physical measurement; coordinates that system with measurement systems of other nations; and furnishes essential services leading to accurate and uniform physical measurements throughout the Nation's scientific community, industry, and commerce.
Page 1-1 - That the functions of the bureau shall consist in the custody of the standards; the comparison of the standards used in scientific investigations, engineering, manufacturing, commerce, and educational institutions with the standards adopted or recognized by the Government; the construction, when necessary, of standards, their multiples and subdivisions; the testing and calibration of standard measuring apparatus; the solution of problems which arise in connection with standards; the determination...
Page ii - This publication contains a descriptive listing, item by item, of most of the test and calibration work done at the National Bureau of Standards with the respective fees.
Page 1-1 - Cooperation with other governmental agencies and with private organizations in the establishment of standard practices, incorporated in codes and specifications. (5) Advisory service to Government agencies on scientific and technical problems. (6) Invention and development of devices to serve special needs of the Government.
Page 1-1 - The development of methods for testing materials, mechanisms, and structures, and the testing of materials, supplies, and equipment, including items purchased for use of Government departments and independent establishments. (d) Cooperation with other governmental agencies and with private organizations in the establishment of standard practices, incorporated in codes and specifications.
Page 1-1 - States for a complete and consistent system of physical measurements, coordinates that system with the measurement systems of other nations, and furnishes essential services leading to accurate and uniform physical measurements throughout the Nation's scientific community, industry, and commerce.
Page 2-22 - Page 43 shunts, current transformers, and voltage (potential) transformers, should be packed in separate boxes to avoid possible damage to the instruments. Heavy pieces should always be shipped in wooden boxes and held in place, if necessary, by checks or cleats. Large transformers, especially those having oilfilled iron cases, should be crated separately and arranged whenever possible so that the terminals can be made accessible for tests without removing the entire crate. (7) The tops of boxes...
Page 1-1 - ... (c) The development of methods for testing materials, mechanisms, and structures, and the testing of materials, supplies, and equipment, including items purchased for use of Government departments and independent establishments. (d) Cooperation with other governmental agencies and with private organizations in the establishment of standard practices, incorporated in codes and specifications.
Page 5-7 - Kc, for bolometer-coupler units is defined as the ratio of the substituted dc power in the bolometer unit on the side arm of the directional coupler to the microwave power incident upon a non-reflecting load connected to the output port of the main arm.