Pressure calibration of Western Electric Co. Type 640AA condenser
microphone or equivalent from 50 to 20,000 Hz at
frequencies. Response given in terms of open-circuit voltage
per unit sound pressure applied to the microphone.
Special measurements not covered by this schedule.

213.012 Hearing equipment.

Description

3.012a

3.012b

Calibration of earphones; applied voltage response as prescribed in the American Standards Association Specification Z24.9-1949, at not more than 20 frequencies between 100 and 10,000 Hz.

Calibration of pure tone audiometers for
nine fixed frequencies.

screening purposes at

3.012z Special measurements not covered by this schedule.

213.013 Sound absorption.

Item

3.013a

Sound absorption

3.013b

Description

coefficient, obtained by

by reverberation room method, using 72 ft2 of material at frequencies of 125, 250, 500, 1,000, 2,000, and 4,000 Hz.

In case of tests on acoustical plasters or paintability tests, any construction work or painting done by the Bureau will be charged to the sponsor in addition to the fee listed.

Sound absorption coefficient by impedance tube method at
in the laboratory on acoustical tiles.

3.013z Special measurements not covered by this schedule.

500 Hz

Engineering Mechanics

213.040 General.

Direct inquiries to, and mark shipments for the attention of: gineering Mechanics

[merged small][merged small][merged small][ocr errors][merged small]
[blocks in formation]

213.041a

Determination of Brinell number of a block to be used for calibration purposes, 5 separate indentations on each specimen.

213.042 Load cells with remote-reading electrical indicators.

(a) Individual load cells or load cell systems must be accompanied by readout or indicating equipment and all associated cables and fixtures.

(b) For the fee quoted, calibration will be made on one machine with up to 10 incremental loads applied consecutively without return to zero load. For each load in excess of 10, an additional fee equal to onetenth of the applicable fee will be charged. For any device requiring the use of more than one machine, a charge will be made covering the cost of the additional work involved.

(c) When devices submitted are found to be unsuitable for test or unreliable, the test may be discontinued and a charge will be made to cover the cost of the work done.

[blocks in formation]

213.042g

Capacity exceeding 112,000 pounds but not exceeding 300,000 pounds:

Compression.

213.042h Tension.

213.042i Tension and compression.

13.042j

Capacity exceeding 300,000 pounds but not exceeding 1,000,000 pounds:

Compression.

[blocks in formation]

(a) These fees apply to all mechanical tests of devices, aterials, and structures performed in the Mechanics Division not covered y other fee schedules.

(b) The charge for special mechanical tests is made on the basis

f the hours of service furnished by members of the staff.

(c) The time shall be computed as the number of official working ours from the time the members of the staff leave the Bureau until they eturn to it plus any overtime spent on the tests.

(d) Where tests require travel outside the limits of 30 miles rom the Bureau, transportation and subsistence charges will be added to he service charge.

[blocks in formation]

13.043a Service of a member of the staff of grade GS-9,

13.043b

grade, per hour.

or any higher

Service of a member of the staff of grades below GS-9, per hour.

213.044 Proving rings.

(a) These fees apply to calibration or recalibration of proving suitable for use as laboratory or transfer standards in accordance th Sections I, II, III, and IV of the Appendix of NBS Circular 454.*

ngs

BS Circular 454, Proving Rings for Calibrating Testing Machines. See NBS Handbook 77, Precision Measurement and Calibration, Vol. II, Heat d Mechanics, p. 573.

so

ith up to 10 independent loads for compression or tension applied. Fees for complete calibrations apply to rings submitted for initial calibration. For each load in excess of 10, an additional fee equal to one-tenth of the applicable fee for complete calibration or recalibration will be charged. For any device requiring the use of two or more machines, a charge will be nade covering the cost of the additional work involved.

(c) When devices submitted are found to be unsuitable for test or unreliable, a test may be discontinued and a charge will be made to cover the cost of the work done.

Item

213.044a

213.044b

213.044c

Complete

Description

calibration of proving rings, capacity not exceeding 10,000 pounds:

Compression.

Tension and compression.

Recalibration of proving rings, capacity not exceeding 10,000 pounds:

Compression.

213.044d Tension and compression.

213.044e

213.044f

213.044g

213.044h

213.044i

=213.044j

Complete calibration of proving rings, capacity exceeding 10,000 pounds but not exceeding 112,000 pounds:

Compression.

Tension and compression.

Recalibration of proving rings, capacity exceeding 10,000 pounds but not exceeding 112,000 pounds:

Compression.

Tension and compression.

Complete calibration of proving rings, capacity exceeding 112,000 pounds but not exceeding 300,000 pounds:

Compression.

Tension and compression.

Recalibration of proving rings, capacity exceeding 112,000 pounds but not exceeding 300,000 pounds:

[blocks in formation]

3.044m

3.044n

3.0440

3.044p

Complete calibration of proving rings, capacity exceeding 300,000 pounds but not exceeding 1,000,000 pounds:

Compression.

Tension and compression.

Recalibration of proving rings, capacity exceeding 300,000 pounds but not exceeding 1,000,000 pounds:

Compression.

Tension and compression.

3.044z Special measurements not covered by this schedule.

213.045 Elastic force measuring devices.

(a) These fees apply to calibration of elastic force measuring vices suitable for use as laboratory or transfer standards.

(b) Before a device is accepted for calibration under this hedule it will be inspected for damage, wear, and operability. Loading rfaces, tension adaptors, and pulling rods must be complete and suitable r use with Bureau equipment. The device must be uniquely and permanently rked with the manufacturer's serial number and rated capacity.

(c) For the fee quoted, calibration will be made on one machine th up to 10 different independent loads for compression or tension plied. Devices will be overloaded repeatedly to approximately 10 percent excess of the manufacturer's rated capacity. A temperature coefficient st be supplied by the submitter of the device.

an additional fee equal to For any device requiring

(d) For each load in excess of 10, e-tenth of the applicable fee will be charged. use of more than one machine, a charge will be made covering the cost the additional work involved.

e

(e) When devices submitted are found to be unsuitable for test unreliable, a test may be discontinued and a charge will be made to ver the cost of the work done.

[blocks in formation]
« PreviousContinue »