Code of Federal Regulations: Containing a Codification of Documents of General Applicability and Future Effect as of December 31, 1948, with Ancillaries and IndexDivision of the Federal Register, the National Archives, 2002 Special edition of the Federal Register, containing a codification of documents of general applicability and future effect ... with ancillaries. |
From inside the book
Results 1-5 of 84
Page 36
... continuous operation at tempera- tures of 374 ° F ( 190 ° C ) ± 18 ° F ( 10 ° C ) . ( iii ) The analyzer fuel shall contain 402 percent hydrogen . The balance shall be helium . The mixture shall con- tain ≤1 part per million equivalent ...
... continuous operation at tempera- tures of 374 ° F ( 190 ° C ) ± 18 ° F ( 10 ° C ) . ( iii ) The analyzer fuel shall contain 402 percent hydrogen . The balance shall be helium . The mixture shall con- tain ≤1 part per million equivalent ...
Page 37
... continuous meas- urement of the flow rate and control of the proportional sampling in the par- ticulate sampling system . ( 7 ) The flow capacity of the system shall be large enough to eliminate water condensation . Ambient air inlet ...
... continuous meas- urement of the flow rate and control of the proportional sampling in the par- ticulate sampling system . ( 7 ) The flow capacity of the system shall be large enough to eliminate water condensation . Ambient air inlet ...
Page 49
... continuous and gas - tight . At a minimum , they shall be made in ac- cordance with American Welding Soci- ety Standard D14.4-77 or meet the test requirements of $ 7.104 with the inter- nal pressure equal to four times the maximum ...
... continuous and gas - tight . At a minimum , they shall be made in ac- cordance with American Welding Soci- ety Standard D14.4-77 or meet the test requirements of $ 7.104 with the inter- nal pressure equal to four times the maximum ...
Page 60
... Continuous and gas - tight ; and ( ii ) Made in accordance with or ex- ceed the American Welding Society Standard AWS D14.4-77 , " Classification and Application of Welded Joints for Machinery and Equipment , " or meet the test ...
... Continuous and gas - tight ; and ( ii ) Made in accordance with or ex- ceed the American Welding Society Standard AWS D14.4-77 , " Classification and Application of Welded Joints for Machinery and Equipment , " or meet the test ...
Page 61
... continuous gas - tight weld . ( 16 ) O - rings , if used in a flame - arrest- ing path , shall meet the following : ( i ) When the flame - arresting path is in one plane , the o - ring shall be located at least one - half the acceptable ...
... continuous gas - tight weld . ( 16 ) O - rings , if used in a flame - arrest- ing path , shall meet the following : ( i ) When the flame - arresting path is in one plane , the o - ring shall be located at least one - half the acceptable ...
Other editions - View all
Common terms and phrases
Administration amended application approval audiogram battery belt blasting borehole brakes certified person chemical circuit circuit breakers clearance coal components conductors conveyors deenergized designated detonating cord detonators devices diesel diesel particulate matter District Manager drill Electrical conductors enclosure engine escapeway examination exhaust exhaust gas explosive material facilities Federal Federal Acquisition Regulation feet fire suppression flame arrester flammable fuel fuse ground hazard health and safety high-voltage hoist inches inspection installed insulated intake intrinsically safe June 29 least loading machine maintained maximum means ment metal methane miners mines minimum mobile equipment MSHA Nonmetal OMB number operator paragraph percent pressure procedures protection record requirements respirable dust revised roof rope safe Safety and Health safety fuse sampling Secretary shaft specified standard storage Subpart surface temperature tion trailing cables trolley underground unit ventilation voltage wires
Popular passages
Page 696 - Planning and Development, Office of Assistant Secretary for Community Services, Office of Comptroller of the Currency Construction Industry Collective Bargaining Commission Consumer Product Safety Commission Cooperative State Research, Education, and Extension Service Copyright Office...
Page 687 - National Counter-intelligence Center (Parts 1800—1899) XIX Central Intelligence Agency (Parts 1900—1999) XX Information Security Oversight Office, National Archives and Records Administration (Parts 2000—2099) XXI National Security Council (Parts 2100—2199...
Page 572 - Manager shall, if he determines that the operator cannot meet the location requirements of §75.1712-6 with respect to any or all of the working places in the mine because of the coal seam thickness or because of other physical restriction, issue a waiver of the requirements of this section and designate an alternative site for installation of such facilities. The waiver issued shall specify each working place to which it shall apply, set forth the reasons for such waiver, and the reasons for designation...
Page 684 - Office of the Assistant Secretary for Housing — Federal Housing Commissioner, Department of Housing and Urban Development (Section 8 Housing Assistance Programs, Section 202 Direct Loan Program, Section 202 Supportive Housing for the Elderly Program and Section 811 Supportive Housing for Persons With Disabilities Program) (Parts 800—899...
Page 257 - Circuit breaker means a device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent setting without injury to itself when properly applied within its rating.
Page 193 - Every party shall have the right to present his case or defense by oral or documentary evidence, to submit rebuttal evidence, and to conduct such cross-examination as may be required for a full and true disclosure of the facts.
Page 370 - Nonferrous. II Material Specifications— Part C— Welding Rods, Electrodes, and Filler Metals. IV Heating Boilers. V Nondestructive Examination. VI Recommended Rules for Care and Operation of Heating Boilers. VII Recommended Rules for Care of Power Boilers. (2) The National Board Inspection Code, a Manual for Boiler and Pressure Vessel Inspectors, 1979, published by the National Board of Boiler and Pressure Vessel Inspectors. CHAPTER AND TITLE I Glossary of Terms.
Page 288 - These gauges, devices and piping shall be designed, installed, operated, maintained, repaired, altered, inspected, and tested by inspectors holding a valid National Board Commission and in accordance with the following listed sections, chapters and appendices: (1) The ASME Boiler and Pressure Vessel Code, 1977, Published by the American Society of Mechanical Engineers. SECTION AND TITLE I Power Boilers. II Material Specifications— Part A— Ferrous. II Material Specifications — Part B— Nonferrous....
Page 696 - Central Intelligence Agency Chief Financial Officer, Office of Child Support Enforcement, Office of Children and Families, Administration for Civil Rights, Commission on Civil Rights, Office for Coast Guard Coast Guard (Great Lakes Pilotage) Commerce Department Census Bureau Economic Affairs, Under Secretary Economic Analysis, Bureau of Economic Development Administration Emergency Management and Assistance...
Page 627 - ... 77.808 Disconnecting devices. Disconnecting devices shall be installed at the beginning of each branch line in high-voltage circuits and they shall be equipped or designed in such a manner that it can be determined by visual observation that the circuit is deenergized when such devices are open.