ProceedingsHenry E. Robinson U.S. National Bureau of Standards, 1970 - 79 pages |
From inside the book
Results 1-5 of 14
Page 11
... wind action , and result in the transfer of large amounts of moisture if leaks are present . Thus , 2 Wilson , A. G. , and Solvason , K. R. , Performance of sealed double - glazing units , J. Can . Ceram Soc . , 31 , 68-82 ( 1962 ) ...
... wind action , and result in the transfer of large amounts of moisture if leaks are present . Thus , 2 Wilson , A. G. , and Solvason , K. R. , Performance of sealed double - glazing units , J. Can . Ceram Soc . , 31 , 68-82 ( 1962 ) ...
Page 12
... wind pres- sures ; and by forces that may develop due to faulty installation . Sealing systems must with- stand the repeated action of these forces and must also retain the necessary physical properties under normal conditions of ...
... wind pres- sures ; and by forces that may develop due to faulty installation . Sealing systems must with- stand the repeated action of these forces and must also retain the necessary physical properties under normal conditions of ...
Page 19
... Wind stresses Sunlight Water Mechanical stresses caused by vibrations . Details shall not be given here , reference is made to earlier publications [ 1 ] , [ 2 ] .1 Of the types of stresses mentioned above , trans- portation and ...
... Wind stresses Sunlight Water Mechanical stresses caused by vibrations . Details shall not be given here , reference is made to earlier publications [ 1 ] , [ 2 ] .1 Of the types of stresses mentioned above , trans- portation and ...
Page 20
... wind pressure . It was found that variations in the atmospheric pressure could be omitted , as the stresses derived ... wind gusts . The pul- sating damper had in the beginning a frequency of 6 periods per minute , but was changed to 5 ...
... wind pressure . It was found that variations in the atmospheric pressure could be omitted , as the stresses derived ... wind gusts . The pul- sating damper had in the beginning a frequency of 6 periods per minute , but was changed to 5 ...
Page 21
... wind stresses in compara- tively exposed places . The wind pressure and air temperature were fixed to follow a day - cycle con- sisting of 4 hours cooling at a low and constant air pressure to an outside air temperature of about -10 ° C ...
... wind stresses in compara- tively exposed places . The wind pressure and air temperature were fixed to follow a day - cycle con- sisting of 4 hours cooling at a low and constant air pressure to an outside air temperature of about -10 ° C ...
Common terms and phrases
20 F cycling A. G. Wilson accelerated aging tests adhesion air space Amstock Andersen Corporation architect ASTM Building Research Institute Bureau of Standards Canada Canadian CGSB CMHC Construction Specifications Institute correlation Curve desiccant dewpoint temperature discussion Durability of Insulating edge seal evaluating F cycling test F to 20 factory-sealed double-glazed failed failure Federal Housing Administration field experience field studies FIGURE fogging Gjelsvik glass thickness industry initial dewpoint installation insulating glass units insulating units laboratory tests large numbers materials McKinley moisture National Bureau nitrile rubber Norwegian Building Research number of units O'Shaughnessy panes percent period polysulfide PPG Industries present pressure problem requirements Robinson Rosen sealant sealed double-glazing units sealed glazing units sealed insulating glass sealing system Seminar SIGMA test Snell Solvason stresses technical test units Thank tion Tore Gjelsvik ultraviolet radiation water spray water vapor weather cycle window units
Popular passages
Page 56 - The authors appreciate the cooperation of the staff of the Division of Building Research of the National Research Council of Canada, particularly Mr.