... double - glazed window units ; factory - sealed insu- lating glass units ; field performance tests , correlation with laboratory tests ; sealant perform- ance ; test methods ; standardized testing . Library of Congress Catalog Card No ...
... double - glazed window units ; factory - sealed insu- lating glass units ; field performance tests , correlation with laboratory tests ; sealant perform- ance ; test methods ; standardized testing . Library of Congress Catalog Card No ...
Page iii
Henry E. Robinson. Foreword The use of factory - sealed double - glass insulating units is increasing in both Government and privately owned buildings . Seal failure on some of the units leads to moisture penetration of the air space ...
Henry E. Robinson. Foreword The use of factory - sealed double - glass insulating units is increasing in both Government and privately owned buildings . Seal failure on some of the units leads to moisture penetration of the air space ...
Page v
... units . Harold J. Rosen 3 1.2 . The need for a method to evaluate the ... sealed double - glazing in Canada . K. R. Solvason and A. G. Wilson 11 2.2 ... sealed glazing units and their correlation with field experience . Tore Gjelsvik 19 ...
... units . Harold J. Rosen 3 1.2 . The need for a method to evaluate the ... sealed double - glazing in Canada . K. R. Solvason and A. G. Wilson 11 2.2 ... sealed glazing units and their correlation with field experience . Tore Gjelsvik 19 ...
Page 1
... units ; standardized testing . Gentlemen : In welcoming you here to participate in the seminar on Durability of Insu ... sealed insulating glass units . The goal , of course , is assured , satisfying performance for periods up to or ...
... units ; standardized testing . Gentlemen : In welcoming you here to participate in the seminar on Durability of Insu ... sealed insulating glass units . The goal , of course , is assured , satisfying performance for periods up to or ...
Page 2
... sealed insulating units is at present quite considerable , and the testing capability required to test all manufacturers ' products in a reasonable time does not exist at present . There is , therefore , an urgent need to develop ...
... sealed insulating units is at present quite considerable , and the testing capability required to test all manufacturers ' products in a reasonable time does not exist at present . There is , therefore , an urgent need to develop ...
Common terms and phrases
20 F cycling A. G. Wilson accelerated aging tests adhesion air space Amstock Andersen Corporation architect ASTM Building Research Institute Bureau of Standards Canada Canadian CGSB CMHC Construction Specifications Institute correlation Curve desiccant dewpoint temperature discussion Durability of Insulating edge seal evaluating F cycling test F to 20 factory-sealed double-glazed failed failure Federal Housing Administration field experience field studies FIGURE fogging Gjelsvik glass thickness industry initial dewpoint installation insulating glass units insulating units laboratory tests large numbers materials McKinley moisture National Bureau nitrile rubber Norwegian Building Research number of units O'Shaughnessy panes percent period polysulfide PPG Industries present pressure problem requirements Robinson Rosen sealant sealed double-glazing units sealed glazing units sealed insulating glass sealing system Seminar SIGMA test Snell Solvason stresses technical test units Thank tion Tore Gjelsvik ultraviolet radiation water spray water vapor weather cycle window units