ProceedingsHenry E. Robinson U.S. National Bureau of Standards, 1970 - 79 pages |
From inside the book
Results 1-5 of 25
Page v
... Problems resulting from early failure of insulating glass units . Willard E. Bryant 7 1.4 . Discussion Session I 9 2. Canadian Experience With an Accelerated Test Method and Acceptance Program 11 2.1 . The development of evaluation ...
... Problems resulting from early failure of insulating glass units . Willard E. Bryant 7 1.4 . Discussion Session I 9 2. Canadian Experience With an Accelerated Test Method and Acceptance Program 11 2.1 . The development of evaluation ...
Page 3
... problem of failure would be for these three parties to join together in research for methods of preventing such failure . Key words : Design ; installation ; materials failure ; production . 1. Introduction Mr. Chairman , for the next ...
... problem of failure would be for these three parties to join together in research for methods of preventing such failure . Key words : Design ; installation ; materials failure ; production . 1. Introduction Mr. Chairman , for the next ...
Page 4
... problems related to build- ing products and their incorporation into complex designs . To reduce the problems the following do's and don'ts are suggested as a guide to select- ing materials and reducing the possibility of a materials ...
... problems related to build- ing products and their incorporation into complex designs . To reduce the problems the following do's and don'ts are suggested as a guide to select- ing materials and reducing the possibility of a materials ...
Page 5
... Problems Resulting from Early Failure of Insulating Glass. 1. Introduction In reviewing the docket on the subject of sealed insulating glass units the other day , I found that as far back as mid - 1964 , shortly after I started with FHA ...
... Problems Resulting from Early Failure of Insulating Glass. 1. Introduction In reviewing the docket on the subject of sealed insulating glass units the other day , I found that as far back as mid - 1964 , shortly after I started with FHA ...
Page 7
... Problems The short term problem presents the builder with a number of questions rather than answers , and these concern how meaningful the warranties are . In other words you have a 5- , 10- , 20 - year warranty . . . are these ...
... Problems The short term problem presents the builder with a number of questions rather than answers , and these concern how meaningful the warranties are . In other words you have a 5- , 10- , 20 - year warranty . . . are these ...
Common terms and phrases
20 F cycling A. G. Wilson accelerated aging tests adhesion air space Amstock Andersen Corporation architect ASTM Building Research Institute Bureau of Standards Canada Canadian CGSB CMHC Construction Specifications Institute correlation Curve desiccant dewpoint temperature discussion Durability of Insulating edge seal evaluating F cycling test F to 20 factory-sealed double-glazed failed failure Federal Housing Administration field experience field studies FIGURE fogging Gjelsvik glass thickness industry initial dewpoint installation insulating glass units insulating units laboratory tests large numbers materials McKinley moisture National Bureau nitrile rubber Norwegian Building Research number of units O'Shaughnessy panes percent period polysulfide PPG Industries present pressure problem requirements Robinson Rosen sealant sealed double-glazing units sealed glazing units sealed insulating glass sealing system Seminar SIGMA test Snell Solvason stresses technical test units Thank tion Tore Gjelsvik ultraviolet radiation water spray water vapor weather cycle window units
Popular passages
Page 56 - The authors appreciate the cooperation of the staff of the Division of Building Research of the National Research Council of Canada, particularly Mr.