ProceedingsHenry E. Robinson U.S. National Bureau of Standards, 1970 - 79 pages |
From inside the book
Results 1-5 of 27
Page 11
... pressure : dew point temperature ; Canadian Government Specifica- tions Board ( CGSB ) standard ; factory - sealed ... pressure differences across the seal . These pressure differences are induced by temperature or barometer pressure ...
... pressure : dew point temperature ; Canadian Government Specifica- tions Board ( CGSB ) standard ; factory - sealed ... pressure differences across the seal . These pressure differences are induced by temperature or barometer pressure ...
Page 12
... pressure differences be- tween the air space and surrounding air due to temperature and barometer pressure changes ; by differential expansion or contraction of compo- nents caused by unequal thermal expansion coeffi- cients and ...
... pressure differences be- tween the air space and surrounding air due to temperature and barometer pressure changes ; by differential expansion or contraction of compo- nents caused by unequal thermal expansion coeffi- cients and ...
Page 13
... pressure . While these initial laboratory tests were being conducted , a few specimens of each brand were exposed to outdoor weather , mounted in a vertical position on a plywood support facing south , and dewpoint temperatures were ...
... pressure . While these initial laboratory tests were being conducted , a few specimens of each brand were exposed to outdoor weather , mounted in a vertical position on a plywood support facing south , and dewpoint temperatures were ...
Page 16
... pressure on the industry for im- provement of the product . Competent manufac- turers have responded and there has been a major increase in the average quality of units since the program began , to the benefit of both customer and ...
... pressure on the industry for im- provement of the product . Competent manufac- turers have responded and there has been a major increase in the average quality of units since the program began , to the benefit of both customer and ...
Page 19
... pressure supply pipe 8. Return pipe 9. Pulsating. 1. Introduction The work on the subject of sealed glazing units at the Norwegian Building Research Institute started back in 1958 , independent of similar work in other countries . The ...
... pressure supply pipe 8. Return pipe 9. Pulsating. 1. Introduction The work on the subject of sealed glazing units at the Norwegian Building Research Institute started back in 1958 , independent of similar work in other countries . The ...
Common terms and phrases
20 F cycling A. G. Wilson accelerated aging tests adhesion air space Amstock Andersen Corporation architect ASTM Building Research Institute Bureau of Standards Canada Canadian CGSB CMHC Construction Specifications Institute correlation Curve desiccant dewpoint temperature discussion Durability of Insulating edge seal evaluating F cycling test F to 20 factory-sealed double-glazed failed failure Federal Housing Administration field experience field studies FIGURE fogging Gjelsvik glass thickness industry initial dewpoint installation insulating glass units insulating units laboratory tests large numbers materials McKinley moisture National Bureau nitrile rubber Norwegian Building Research number of units O'Shaughnessy panes percent period polysulfide PPG Industries present pressure problem requirements Robinson Rosen sealant sealed double-glazing units sealed glazing units sealed insulating glass sealing system Seminar SIGMA test Snell Solvason stresses technical test units Thank tion Tore Gjelsvik ultraviolet radiation water spray water vapor weather cycle window units
Popular passages
Page 56 - The authors appreciate the cooperation of the staff of the Division of Building Research of the National Research Council of Canada, particularly Mr.