ProceedingsHenry E. Robinson U.S. National Bureau of Standards, 1970 - 79 pages |
From inside the book
Results 1-5 of 34
Page ii
... laboratory tests ; double - glazed window units ; factory - sealed insu- lating glass units ; field performance tests , correlation with laboratory tests ; sealant perform- ance ; test methods ; standardized testing . Library of ...
... laboratory tests ; double - glazed window units ; factory - sealed insu- lating glass units ; field performance tests , correlation with laboratory tests ; sealant perform- ance ; test methods ; standardized testing . Library of ...
Page 1
... laboratory tests , in as short a time as possible , the prospective durability in service of sealed insulating glass units . The goal , of course , is assured , satisfying performance for periods up to or beyond the expected life of a ...
... laboratory tests , in as short a time as possible , the prospective durability in service of sealed insulating glass units . The goal , of course , is assured , satisfying performance for periods up to or beyond the expected life of a ...
Page 13
... laboratory exposure directly to field condi- tions . It was accepted from the beginning that the test provided only a basis for comparing the be- havior of sealing systems under conditions of fluctuating mechanical stress and ...
... laboratory exposure directly to field condi- tions . It was accepted from the beginning that the test provided only a basis for comparing the be- havior of sealing systems under conditions of fluctuating mechanical stress and ...
Page 15
... tests were conducted on specimens , from all manufac- turers , that had met the other test requirements . Among some ... laboratory as well as out- door exposure tests indicate a steady and marked improvement in the quality of units ...
... tests were conducted on specimens , from all manufac- turers , that had met the other test requirements . Among some ... laboratory as well as out- door exposure tests indicate a steady and marked improvement in the quality of units ...
Page 17
... tests . We find them effective . Mr. McKinley : Yes , Mr. O'Shaughnessy . Mr. R. O'Shaughnessy : Mr. Wilson , in the ... laboratory weathering test ? Mr. Solvason : The later sets that have gone on the field are samples of those which have ...
... tests . We find them effective . Mr. McKinley : Yes , Mr. O'Shaughnessy . Mr. R. O'Shaughnessy : Mr. Wilson , in the ... laboratory weathering test ? Mr. Solvason : The later sets that have gone on the field are samples of those which have ...
Common terms and phrases
20 F cycling A. G. Wilson accelerated aging tests adhesion air space Amstock Andersen Corporation architect ASTM Building Research Institute Bureau of Standards Canada Canadian CGSB CMHC Construction Specifications Institute correlation Curve desiccant dewpoint temperature discussion Durability of Insulating edge seal evaluating F cycling test F to 20 factory-sealed double-glazed failed failure Federal Housing Administration field experience field studies FIGURE fogging Gjelsvik glass thickness industry initial dewpoint installation insulating glass units insulating units laboratory tests large numbers materials McKinley moisture National Bureau nitrile rubber Norwegian Building Research number of units O'Shaughnessy panes percent period polysulfide PPG Industries present pressure problem requirements Robinson Rosen sealant sealed double-glazing units sealed glazing units sealed insulating glass sealing system Seminar SIGMA test Snell Solvason stresses technical test units Thank tion Tore Gjelsvik ultraviolet radiation water spray water vapor weather cycle window units
Popular passages
Page 56 - The authors appreciate the cooperation of the staff of the Division of Building Research of the National Research Council of Canada, particularly Mr.