ProceedingsHenry E. Robinson U.S. National Bureau of Standards, 1970 - 79 pages |
From inside the book
Results 1-5 of 16
Page
... Involved in the Saturating of Roofing Felts . 30 cents BSS20 . Proceedings of a Seminar on the Durability of Insulating Glass . 75 cents BSS21 . Algorithms for Psychrometric Calculations . 55 cents BSS22 . Investigation of Performance ...
... Involved in the Saturating of Roofing Felts . 30 cents BSS20 . Proceedings of a Seminar on the Durability of Insulating Glass . 75 cents BSS21 . Algorithms for Psychrometric Calculations . 55 cents BSS22 . Investigation of Performance ...
Page 3
... involved with additional cost as a result of a failure of insulating glass , that I can best address myself to the subject if I speak about the area of involvement of each of us - architects who design , manufacturers who produce , and ...
... involved with additional cost as a result of a failure of insulating glass , that I can best address myself to the subject if I speak about the area of involvement of each of us - architects who design , manufacturers who produce , and ...
Page 12
... involved , there FIGURE 1. Weathering apparatus for sealed double - glaz- ing units . was considerable incentive to use small specimens . A size of 14 by 20 in . ( 35.5 by 51 cm ) was se- lected , somewhat arbitrarily as a practical ...
... involved , there FIGURE 1. Weathering apparatus for sealed double - glaz- ing units . was considerable incentive to use small specimens . A size of 14 by 20 in . ( 35.5 by 51 cm ) was se- lected , somewhat arbitrarily as a practical ...
Page 17
... involved in widespread failures . We have this kind of evidence , but we don't have any statistics on what is happening in a general way in respect to units as they are presently being manufactured . Mr. McKinley : Mr. Rosen . Mr. Rosen ...
... involved in widespread failures . We have this kind of evidence , but we don't have any statistics on what is happening in a general way in respect to units as they are presently being manufactured . Mr. McKinley : Mr. Rosen . Mr. Rosen ...
Page 19
... involved 2,040 units . In general there is a good correlation between lab tests and field studies . Key words : Accelerated test program , climatic strains , dew formation time , dewpoint temperature , field studies , glass - to - metal ...
... involved 2,040 units . In general there is a good correlation between lab tests and field studies . Key words : Accelerated test program , climatic strains , dew formation time , dewpoint temperature , field studies , glass - to - metal ...
Common terms and phrases
20 F cycling A. G. Wilson accelerated aging tests adhesion air space Amstock Andersen Corporation architect ASTM Building Research Institute Bureau of Standards Canada Canadian CGSB CMHC Construction Specifications Institute correlation Curve desiccant dewpoint temperature discussion Durability of Insulating edge seal evaluating F cycling test F to 20 factory-sealed double-glazed failed failure Federal Housing Administration field experience field studies FIGURE fogging Gjelsvik glass thickness industry initial dewpoint installation insulating glass units insulating units laboratory tests large numbers materials McKinley moisture National Bureau nitrile rubber Norwegian Building Research number of units O'Shaughnessy panes percent period polysulfide PPG Industries present pressure problem requirements Robinson Rosen sealant sealed double-glazing units sealed glazing units sealed insulating glass sealing system Seminar SIGMA test Snell Solvason stresses technical test units Thank tion Tore Gjelsvik ultraviolet radiation water spray water vapor weather cycle window units