ProceedingsHenry E. Robinson U.S. National Bureau of Standards, 1970 - 79 pages |
From inside the book
Results 1-5 of 44
Page
... Field Burnout Tests of Apartment Dwelling Units . 25 cents BSS11 . Fire Resistance of Steel Deck Floor Assemblies . 25 cents BSS12 . Performance of Square - Edged Orifices and Orifice - Target Combinations as Air Mixers . 15 cents BSS13 ...
... Field Burnout Tests of Apartment Dwelling Units . 25 cents BSS11 . Fire Resistance of Steel Deck Floor Assemblies . 25 cents BSS12 . Performance of Square - Edged Orifices and Orifice - Target Combinations as Air Mixers . 15 cents BSS13 ...
Page ii
... field experience . A review of current practices leading to new test methods and stand- ards was also presented , and a " round robin " program that would compare various test meth- ods now employed in the industry was proposed ...
... field experience . A review of current practices leading to new test methods and stand- ards was also presented , and a " round robin " program that would compare various test meth- ods now employed in the industry was proposed ...
Page v
... field experience ; expected field life . James D. Gwyn སོ་ སོ་ ཚོ་ ཆ 4.3 . Test methods and field experience with double - glazed units . R. J. Mazzoni and G. H. Bowser 4.4 . Insulated glass sealants - function and types . James A. Box ...
... field experience ; expected field life . James D. Gwyn སོ་ སོ་ ཚོ་ ཆ 4.3 . Test methods and field experience with double - glazed units . R. J. Mazzoni and G. H. Bowser 4.4 . Insulated glass sealants - function and types . James A. Box ...
Page 5
... field offices had ex- pressed concern and asked for guidance in select- ing suitable sealed insulating glass units . The increase in the number of manufacturers and types of manufacture , coupled with the ab- sence of a way to evaluate ...
... field offices had ex- pressed concern and asked for guidance in select- ing suitable sealed insulating glass units . The increase in the number of manufacturers and types of manufacture , coupled with the ab- sence of a way to evaluate ...
Page 11
... field performance presented a difficult problem to the Central Mortgage and Housing Corporation ( CMHC ) . This Crown Company has responsibility for administering the National Housing Act of Canada , including the determination of ...
... field performance presented a difficult problem to the Central Mortgage and Housing Corporation ( CMHC ) . This Crown Company has responsibility for administering the National Housing Act of Canada , including the determination of ...
Common terms and phrases
20 F cycling A. G. Wilson accelerated aging tests adhesion air space Amstock Andersen Corporation architect ASTM Building Research Institute Bureau of Standards Canada Canadian CGSB CMHC Construction Specifications Institute correlation Curve desiccant dewpoint temperature discussion Durability of Insulating edge seal evaluating F cycling test F to 20 factory-sealed double-glazed failed failure Federal Housing Administration field experience field studies FIGURE fogging Gjelsvik glass thickness industry initial dewpoint installation insulating glass units insulating units laboratory tests large numbers materials McKinley moisture National Bureau nitrile rubber Norwegian Building Research number of units O'Shaughnessy panes percent period polysulfide PPG Industries present pressure problem requirements Robinson Rosen sealant sealed double-glazing units sealed glazing units sealed insulating glass sealing system Seminar SIGMA test Snell Solvason stresses technical test units Thank tion Tore Gjelsvik ultraviolet radiation water spray water vapor weather cycle window units
Popular passages
Page 56 - The authors appreciate the cooperation of the staff of the Division of Building Research of the National Research Council of Canada, particularly Mr.