ProceedingsHenry E. Robinson U.S. National Bureau of Standards, 1970 - 79 pages |
From inside the book
Results 1-5 of 11
Page ii
... double - glazed window units ; factory - sealed insu- lating glass units ; field performance tests , correlation with laboratory tests ; sealant perform- ance ; test methods ; standardized testing . Library of Congress Catalog Card No ...
... double - glazed window units ; factory - sealed insu- lating glass units ; field performance tests , correlation with laboratory tests ; sealant perform- ance ; test methods ; standardized testing . Library of Congress Catalog Card No ...
Page v
... double - glazing in Canada . K. R. Solvason and A. G. Wilson 11 2.2 ... glazed units . R. J. Mazzoni and G. H. Bowser 4.4 . Insulated glass sealants ... double - glazed window units . Henry E. Robinson 49 5.2 . Discussion Session V 59 ...
... double - glazing in Canada . K. R. Solvason and A. G. Wilson 11 2.2 ... glazed units . R. J. Mazzoni and G. H. Bowser 4.4 . Insulated glass sealants ... double - glazed window units . Henry E. Robinson 49 5.2 . Discussion Session V 59 ...
Page 2
... double glazed window unit durability . It is our expectation that these presenta- tions and deliberations will lead to the development of uniform test methods for measuring in meaningful terms the serviceability and durability of ...
... double glazed window unit durability . It is our expectation that these presenta- tions and deliberations will lead to the development of uniform test methods for measuring in meaningful terms the serviceability and durability of ...
Page 37
Henry E. Robinson. 4.3 . Test Methods and Field Experience With Double - Glazed Units R. J. Mazzoni and G. H. Bowser Glass Research Laboratory , PPG Industries , Creighton , Pennsylvania 15030 Performance criteria for double - glazed ...
Henry E. Robinson. 4.3 . Test Methods and Field Experience With Double - Glazed Units R. J. Mazzoni and G. H. Bowser Glass Research Laboratory , PPG Industries , Creighton , Pennsylvania 15030 Performance criteria for double - glazed ...
Page 42
... double- glazed window units . Norwegian Building Research Institute , Report No. 33 , Oslo , 1962 ( in English ) . [ 3 ] Wilson , A. G. , Solvason , K. R. , Nowak , E. S. , Eval- uation of factory sealed double - glazed window units ...
... double- glazed window units . Norwegian Building Research Institute , Report No. 33 , Oslo , 1962 ( in English ) . [ 3 ] Wilson , A. G. , Solvason , K. R. , Nowak , E. S. , Eval- uation of factory sealed double - glazed window units ...
Common terms and phrases
20 F cycling A. G. Wilson accelerated aging tests adhesion air space Amstock Andersen Corporation architect ASTM Building Research Institute Bureau of Standards Canada Canadian CGSB CMHC Construction Specifications Institute correlation Curve desiccant dewpoint temperature discussion Durability of Insulating edge seal evaluating F cycling test F to 20 factory-sealed double-glazed failed failure Federal Housing Administration field experience field studies FIGURE fogging Gjelsvik glass thickness industry initial dewpoint installation insulating glass units insulating units laboratory tests large numbers materials McKinley moisture National Bureau nitrile rubber Norwegian Building Research number of units O'Shaughnessy panes percent period polysulfide PPG Industries present pressure problem requirements Robinson Rosen sealant sealed double-glazing units sealed glazing units sealed insulating glass sealing system Seminar SIGMA test Snell Solvason stresses technical test units Thank tion Tore Gjelsvik ultraviolet radiation water spray water vapor weather cycle window units
Popular passages
Page 56 - The authors appreciate the cooperation of the staff of the Division of Building Research of the National Research Council of Canada, particularly Mr.