ProceedingsHenry E. Robinson U.S. National Bureau of Standards, 1970 - 79 pages |
From inside the book
Results 1-5 of 30
Page 11
... FIGURE 3. High humidity cycling cabinet . 2.2. 1. Introduction Over the past 10 years a large number of manu- facturers of factory - sealed double - glazing units have entered the Canadian market , and there has been an increasing use of ...
... FIGURE 3. High humidity cycling cabinet . 2.2. 1. Introduction Over the past 10 years a large number of manu- facturers of factory - sealed double - glazing units have entered the Canadian market , and there has been an increasing use of ...
Page 12
... figure 1 . The dewpoint temperature of the air space after exposure to the weather cycle was taken as the criterion of seal adequacy . Because of the possibility of wide variations in quality from faults in the assembly process , it was ...
... figure 1 . The dewpoint temperature of the air space after exposure to the weather cycle was taken as the criterion of seal adequacy . Because of the possibility of wide variations in quality from faults in the assembly process , it was ...
Page 13
... FIGURE 2. Outside exposure racks . At this time , development was begun on a fur- ther qualifying test procedure involving exposure of the units to an elevated temperature cycle ( 70 to 130 ° F ) ( 21 to 54 ° C ) and high humidity ...
... FIGURE 2. Outside exposure racks . At this time , development was begun on a fur- ther qualifying test procedure involving exposure of the units to an elevated temperature cycle ( 70 to 130 ° F ) ( 21 to 54 ° C ) and high humidity ...
Page 14
Henry E. Robinson. GLAZING UNITS FIGURE 3. High humidity cycling cabinet . 2.2 . DISCUSSION SESSION II 3. Norwegian Experience With Accelerated. WATER SPRAY BAFFLE - = 45 ° F ( 7 ° C. ) COOLING WATER INDICATES AIR CIRCULATION CREATED by ...
Henry E. Robinson. GLAZING UNITS FIGURE 3. High humidity cycling cabinet . 2.2 . DISCUSSION SESSION II 3. Norwegian Experience With Accelerated. WATER SPRAY BAFFLE - = 45 ° F ( 7 ° C. ) COOLING WATER INDICATES AIR CIRCULATION CREATED by ...
Page 15
... FIGURE 4. Ultraviolet fogging test apparatus . To assess the implications of the method , tests were conducted on ... figures include the results of tests carried out for manufacturers for purposes of product development and ...
... FIGURE 4. Ultraviolet fogging test apparatus . To assess the implications of the method , tests were conducted on ... figures include the results of tests carried out for manufacturers for purposes of product development and ...
Common terms and phrases
20 F cycling A. G. Wilson accelerated aging tests adhesion air space Amstock Andersen Corporation architect ASTM Building Research Institute Bureau of Standards Canada Canadian CGSB CMHC Construction Specifications Institute correlation Curve desiccant dewpoint temperature discussion Durability of Insulating edge seal evaluating F cycling test F to 20 factory-sealed double-glazed failed failure Federal Housing Administration field experience field studies FIGURE fogging Gjelsvik glass thickness industry initial dewpoint installation insulating glass units insulating units laboratory tests large numbers materials McKinley moisture National Bureau nitrile rubber Norwegian Building Research number of units O'Shaughnessy panes percent period polysulfide PPG Industries present pressure problem requirements Robinson Rosen sealant sealed double-glazing units sealed glazing units sealed insulating glass sealing system Seminar SIGMA test Snell Solvason stresses technical test units Thank tion Tore Gjelsvik ultraviolet radiation water spray water vapor weather cycle window units
Popular passages
Page 56 - The authors appreciate the cooperation of the staff of the Division of Building Research of the National Research Council of Canada, particularly Mr.