Journal of Research of the National Bureau of Standards, Volumes 91-92National Bureau of Standards, 1986 |
From inside the book
Results 1-5 of 87
Page 19
... approximately 2 ppm by weight of other anions and cations , while solution 99-2 contained approximately 10 ppm of other ions . The second group of solutions ( 99-3 and 99-4 ) , consisting of two reference HCl solutions , was prepared in ...
... approximately 2 ppm by weight of other anions and cations , while solution 99-2 contained approximately 10 ppm of other ions . The second group of solutions ( 99-3 and 99-4 ) , consisting of two reference HCl solutions , was prepared in ...
Page 22
... approximately equal to two standard deviations for the between the labora- tory component of variability observed in our inter- laboratory study [ 8 ] . Table 6. Measured normalized pH of five acid solutions . PH Normalized Solution to ...
... approximately equal to two standard deviations for the between the labora- tory component of variability observed in our inter- laboratory study [ 8 ] . Table 6. Measured normalized pH of five acid solutions . PH Normalized Solution to ...
Page 34
... Approximately 2000 bottles of each level were prepared . 2.1 Bottle Cleaning Based on earlier research [ 1 ] , low density poly- ethylene ( LDPE ) bottles ( 60 - mL capacity ) were chosen for this project . Over 4000 bottles were ...
... Approximately 2000 bottles of each level were prepared . 2.1 Bottle Cleaning Based on earlier research [ 1 ] , low density poly- ethylene ( LDPE ) bottles ( 60 - mL capacity ) were chosen for this project . Over 4000 bottles were ...
Page 35
... Approximately 170 liters of 2694 - I and approximately 150 liters of 2694 - II were prepared in February 1985 , according to the following procedure . The calculated amounts of each of stock solutions # 1 through # 9 , ( see table 3 ) ...
... Approximately 170 liters of 2694 - I and approximately 150 liters of 2694 - II were prepared in February 1985 , according to the following procedure . The calculated amounts of each of stock solutions # 1 through # 9 , ( see table 3 ) ...
Page 78
... approximately 50 per year , bringing the number of banked specimens to about 500. After the first year of human liver collection , the sample collection protocol was evaluated with respect to such items as : initial set - up costs for ...
... approximately 50 per year , bringing the number of banked specimens to about 500. After the first year of human liver collection , the sample collection protocol was evaluated with respect to such items as : initial set - up costs for ...
Other editions - View all
Common terms and phrases
analysis analytical atomic beam BIPM Bureau of Standards calculated calibration calorimeter cell Chem chemical components constant correction detector determined developed displacement effects electrode spacing electron energy Engineering enthalpy equation error estimated evaluation experiment experimental factor Federal finite element flaw frequency function Gaithersburg Green's function impact instrument interactions International ionization chamber isotopic Josephson effect Journal of Research Laboratory linewidth measurement ment metal method metrology microphone National Bureau obtained optical oxygen photodiode Phys physical plate precision procedure quantum Hall effect radiation range ratio S-wave sample scanning shown in figure solution specimen spectral SPRT's SQUID standard deviation Standard Reference Materials Standards Gaithersburg superconducting surements surface technical techniques temperature thermal thermopile tion trace element triple point tunneling uncertainty vacuum values voltage wave waveform wavelength
Popular passages
Page 241 - Monographs — Major contributions to the technical literature on various subjects related to the Bureau's scientific and technical activities. Handbooks — Recommended codes of engineering and industrial practice (including safety codes) developed in cooperation with interested industries, professional organizations, and regulatory bodies. Special Publications — Include proceedings of conferences sponsored by NBS.
Page 263 - Certain commercial equipment, instruments, or materials are identified in this paper in order to adequately specify the experimental procedure. Such identification does not imply recommendation or endorsement by the National...
Page 112 - JOURNAL OF RESEARCH— The Journal of Research of the National Bureau of Standards reports NBS research and development in those disciplines of the physical and engineering sciences in which the Bureau is active. These include physics, chemistry, engineering, mathematics, and computer sciences. Papers cover a broad range of subjects, with major emphasis on measurement methodology, and the basic technology underlying standardization. Also included from time to time are survey articles on topics closely...
Page 345 - Studies or reports which are complete in themselves but restrictive in their treatment of a subject. Analogous to monographs but not so comprehensive in scope or definitive in treatment of the subject area. Often serve as a vehicle for final reports of work performed at NBS under the sponsorship of other
Page 78 - The Bureau's overall goal is to strengthen and advance the Nation's science and technology and facilitate their effective application for public benefit. To this end, the Bureau conducts research and provides...
Page 112 - NBS administers this program as a supplement to the activities of the private sector standardizing organizations. Consumer Information Series — Practical information, based on NBS research and experience, covering areas of interest to the consumer. Easily understandable language and illustrations provide useful background knowledge for shopping in today's technological marketplace.
Page 15 - The metre is the length equal to 1 650 763.73 wavelengths in vacuum of the radiation corresponding to the transition between the levels 2p,0 and 5d5 of the krypton-86 atom.
Page 345 - Bureau conducts research and provides: (1) a basis for the Nation's physical measurement system, (2) scientific and technological services for industry and government, (3) a technical basis for equity in trade, and (4) technical services to promote public safety.
Page 41 - NBS pursuant to the Federal Property and Administrative Services Act of 1949 as amended, Public Law 89-306 (79 Stat. 1127), and as implemented by Executive Order 11717 (38 FR 12315, dated May 11, 1973) and Part 6 of Title 15 CFR (Code of Federal Regulations).
Page 311 - States of a complete and consistent system of physical measurement; coordinates that system with measurement systems of other nations; and furnishes essential services leading to accurate and uniform physical measurements throughout the Nation's scientific community, industry, and commerce.