... the water for 1 hour . While still hot , transfer the water to a narrow mouth screw - cap bottle under zero- headspace and seal with a Teflon - lined septum and 68 Pt . 261 , App . II 40 CFR Ch . I ( 7-1-92 Edition )
... the water for 1 hour . While still hot , transfer the water to a narrow mouth screw - cap bottle under zero- headspace and seal with a Teflon - lined septum and 68 Pt . 261 , App . II 40 CFR Ch . I ( 7-1-92 Edition )
Page 69
... Teflon - lined septum capped vials and stored at 4 ° C . Samples should be opened only immediately prior to extraction ) . 6.6 TCLP extracts should be prepared for analysis and analyzed as soon as possible following extraction ...
... Teflon - lined septum capped vials and stored at 4 ° C . Samples should be opened only immediately prior to extraction ) . 6.6 TCLP extracts should be prepared for analysis and analyzed as soon as possible following extraction ...
Page 72
... Teflon - coated sieve should be used to avoid contamination of the sample . 7.2.11 Determine the amount of extrac- tion fluid to add to the extractor vessel as follows : Weight of extraction fluid = 20x percent solids ( section 7.1.1 ) ...
... Teflon - coated sieve should be used to avoid contamination of the sample . 7.2.11 Determine the amount of extrac- tion fluid to add to the extractor vessel as follows : Weight of extraction fluid = 20x percent solids ( section 7.1.1 ) ...
Page 73
1985-1999. tightly ( it is recommended that Teflon tape be used to ensure a tight seal ) , secure in rotary agitation device , and rotate at 30 ± 2 rpm for 18 ± 2 hours . Ambient temperature ( i.e. , temperature of room in which extrac ...
1985-1999. tightly ( it is recommended that Teflon tape be used to ensure a tight seal ) , secure in rotary agitation device , and rotate at 30 ± 2 rpm for 18 ± 2 hours . Ambient temperature ( i.e. , temperature of room in which extrac ...
Page 81
... Teflon - lined septum. A A METHOD 1311 START Use a sub - sample of waste A Separate liquids from solids with What is the % 0.6 0.8 um solids in the glass fiber waste ? filter 100 % Discard solids Examine solids Liquid Separate liquids ...
... Teflon - lined septum. A A METHOD 1311 START Use a sub - sample of waste A Separate liquids from solids with What is the % 0.6 0.8 um solids in the glass fiber waste ? filter 100 % Discard solids Examine solids Liquid Separate liquids ...
Other editions - View all
Common terms and phrases
1,1,1-trichloroethane 90 days accordance acid amended analysis applicable approved ardous waste Benzene Budget under control cadmium carbon certification chapter chemical chloride chromium cility closure plan compliance comply concentration contained control device cyanide demonstrate determine disposal drip pad electroplating emissions EPA Hazardous Waste equipment extraction facility feed rate filter final closure financial assurance gional Administrator grab samples ground water hazardous constituents hazardous waste management human health incinerator July 17 July 26 landfill leachate letter of credit liability liner liquid listed materials ment metals method ous waste owner or operator period permit Phenol post-closure plan priority pollutant procedures quirements RCRA Regional Administrator regulations requirements selenium sludges EPA Hazardous solid waste standards submit subpart surety bond surface impoundment tank system Tetrachloroethylene tion transporter treatment sludges EPA trust fund U.S. EPA valve waste contained waste management waste management unit wastewater treatment sludges