The Code of Federal Regulations of the United States of AmericaU.S. Government Printing Office, 1997 The Code of Federal Regulations is the codification of the general and permanent rules published in the Federal Register by the executive departments and agencies of the Federal Government. |
From inside the book
Results 1-5 of 100
Page 70
... flow rate determined using table 19-1 of EPA Reference Method 19 or a State - approved method , and the hourly average steam or feedwater flow rate . ( ii ) The daily total nitrogen oxides emissions shall be calculated as the sum of the ...
... flow rate determined using table 19-1 of EPA Reference Method 19 or a State - approved method , and the hourly average steam or feedwater flow rate . ( ii ) The daily total nitrogen oxides emissions shall be calculated as the sum of the ...
Page 128
... flow rates at the inlet and outlet of the wet scrubber and the inlet CO2 concentration may be used to determine the ... rate of effluent gas be- fore the wet scrubber , dscm / min ( dscf / min ) . Qdo - volumetric flow rate of effluent ...
... flow rates at the inlet and outlet of the wet scrubber and the inlet CO2 concentration may be used to determine the ... rate of effluent gas be- fore the wet scrubber , dscm / min ( dscf / min ) . Qdo - volumetric flow rate of effluent ...
Page 178
... flow rate of the effluent gas , dscm / hr ( dscf / hr ) . P = production rate of 100 percent H2SO4 , met- ric ton / hr ( ton / hr ) . K = conversion factor , 1000 g / kg ( 1.0 lb / lb ) . ( 2 ) Method 8 shall be used to deter- mine the ...
... flow rate of the effluent gas , dscm / hr ( dscf / hr ) . P = production rate of 100 percent H2SO4 , met- ric ton / hr ( ton / hr ) . K = conversion factor , 1000 g / kg ( 1.0 lb / lb ) . ( 2 ) Method 8 shall be used to deter- mine the ...
Page 185
... flow rate of effluent gas , dscm / hr ( dscf / hr ) . R - Coke burn - off rate , kg coke / hr ( 1000 lb coke / hr ) . K - Conversion factor , 1.0 ( kg / g ) / ( 1000 kg ) [ 103 lb / ( 1000 lb ) ] . ( 2 ) Method 5B or 5F is to be used to ...
... flow rate of effluent gas , dscm / hr ( dscf / hr ) . R - Coke burn - off rate , kg coke / hr ( 1000 lb coke / hr ) . K - Conversion factor , 1.0 ( kg / g ) / ( 1000 kg ) [ 103 lb / ( 1000 lb ) ] . ( 2 ) Method 5B or 5F is to be used to ...
Page 188
... rate equations , and , if requested , auxiliary / supple- mental fuel SOx credits , have been sub- mitted to and ... flow rate cor- rected to standard conditions , dscm / hr 1,000 conversion factor , g to kg ( 10 ) Sulfur oxides ...
... rate equations , and , if requested , auxiliary / supple- mental fuel SOx credits , have been sub- mitted to and ... flow rate cor- rected to standard conditions , dscm / hr 1,000 conversion factor , g to kg ( 10 ) Sulfur oxides ...
Other editions - View all
Common terms and phrases
acid Administrator affected facility Applicability and designation approved ASTM atmosphere average calculated calendar month calibration carbon cility coal coating operation coating solids combustion comply concentration control device deter determined dry basis duct emis emission limit emission rate equipment erator fected flue gas desulfurization following equation fossil fuel furnace gas stream gas turbine gases heat input incinerator initial performance test inlet install kilograms landfill leak liquid located mass of VOC means measured megagrams ment methods and procedures monitoring device municipal solid waste municipal waste combustor ng/J nitrogen oxides opacity operator subject owner or operator oxides emission oxygen particulate matter percent performance test required period pitot tube pressure probe provisions record reduction Reference Method sampling sions SO₂ solid waste solvent stack standard steam generating unit storage subpart sulfur dioxide temperature Test methods tion traverse points vapor vent stream VOC emissions VOC's volumetric flow rate weight
Popular passages
Page 329 - All decisions, including initial, recommended, and tentative decisions, are a part of the record and shall include a statement of— (A) findings and conclusions, and the reasons or basis . therefor, on all the material issues of fact, law, or discretion presented on the record; and (B) the appropriate rule, order, sanction, relief, or denial thereof.
Page 65 - standard of performance" means a standard for emissions of air pollutants which reflects the degree of emission limitation achievable through the application of the best system of emission reduction which (taking into account the cost of achieving such reduction and any nonair quality health and environmental impact and energy requirements) the Administrator determines has been adequately demonstrated.
Page 91 - Electric utility combined cycle gas turbine means any combined cycle gas turbine used for electric generation that is constructed for the purpose of supplying more than one-third of its potential electric output capacity and more than 25 MW electrical output to any utility power distribution system for sale. Any steam...
Page 25 - Office of Environmental Quality Control, Department of Health and Environmental Control, 2600 Bull Street, Columbia, SC 29201.
Page 16 - modification* means any physical change in, or change in the method of operation of, a stationary source which increases the amount of any air pollutant emitted by such source or which results in the emission of any air pollutant not previously emitted. (5) The term "owner .or operator' means any person who owns, leases, operates, controls, or supervises a stationary source.
Page 648 - Unless otherwise indicated, it is intended that all reagents conform to the specifications established by the Committee on Analytical Reagents of the American Chemical Society, where such specifications are available; otherwise, use the best available grade.
Page 584 - Devorkin, Howard, et al. Air Pollution Source Testing Manual. Air Pollution Control District, Los Angeles, Calif. November, 1963. 3. Methods for Determination of Velocity, Volume, Dust and Mist Content of Gases.
Page 192 - Fossil fuel" means natural gas, petroleum, coal, and any form of solid, liquid, or gaseous fuel derived from such materials for the purpose of creating useful heat.
Page 223 - Straight kraft recovery furnace means a furnace used to recover chemicals consisting primarily of sodium and sulfur compounds by burning black liquor which on a quarterly basis contains 7 weight percent or less of the total pulp solids from the neutral sulfite semichemical process or has green liquor sulfidity of 28 percent or less. (j) Cross recovery furnace...
Page 91 - Fossil-fuel fired steam generating •unit means a furnace or boiler used in the process of burning fossil fuel for the purpose of producing steam by heat transfer. (b) Fossil fuel...