Smoke and Gases Produced by Burning Aircraft Interior MaterialsU.S. Government Printing Office, 1969 - 27 pages |
From inside the book
Results 1-5 of 10
Page
... References 7. Appendix 1. Gas analysis . 7.1 . Colorimetric indicator tubes 7.2 . Specific ion electrode . 8. Appendix 2. Materials description . 12 3 3 3 4 8 9 11 11 12 12 13 16 9. Appendix 3. Summary of test results - smoke and gas ...
... References 7. Appendix 1. Gas analysis . 7.1 . Colorimetric indicator tubes 7.2 . Specific ion electrode . 8. Appendix 2. Materials description . 12 3 3 3 4 8 9 11 11 12 12 13 16 9. Appendix 3. Summary of test results - smoke and gas ...
Page 1
... reference spectra of known compositions . When some estimate of the percentage composition of blends or mixtures was ... references on page 11 . 3. Test Results and Analysis 1 Architecture Contents Page Introduction Test methods Material ...
... reference spectra of known compositions . When some estimate of the percentage composition of blends or mixtures was ... references on page 11 . 3. Test Results and Analysis 1 Architecture Contents Page Introduction Test methods Material ...
Page 2
... reference spectra identified by trade name from the literature that very little doubt existed as to source . 2.2 . Smoke Measurements The smoke level was determined by measuring the progressive attenuation of a light beam passed through ...
... reference spectra identified by trade name from the literature that very little doubt existed as to source . 2.2 . Smoke Measurements The smoke level was determined by measuring the progressive attenuation of a light beam passed through ...
Page 3
... references to the toxic hazard limits of these gases are discussed in appendix 1. Where HCl was one of the products , in many cases the gas was also absorbed in water and analyzed by a chlorine ion electrode to provide a more accurate ...
... references to the toxic hazard limits of these gases are discussed in appendix 1. Where HCl was one of the products , in many cases the gas was also absorbed in water and analyzed by a chlorine ion electrode to provide a more accurate ...
Page 9
... References 7. Appendix 1. Gas Analysis TABLE. Sampling was performed sequentially , proceed- ing generally from HCl and HF to HCN to CO , and was initiated when optical density of the smoke approached its peak . This procedure was ...
... References 7. Appendix 1. Gas Analysis TABLE. Sampling was performed sequentially , proceed- ing generally from HCl and HF to HCN to CO , and was initiated when optical density of the smoke approached its peak . This procedure was ...
Common terms and phrases
400 Maximum Smoke acetate adsorption Aircraft Interior Materials appendix asbestos Building Science Series calibration cents CHLOROPRENE cm³ cm³/min colorimetric indicator tubes colorimetric tubes components concen copolymer D₁ density of 16 density of smoke dilution Exposure Value Fabric UC film flaming and smoldering ft² gas concentrations gas detector tubes gaseous products gases Glass fiber HCl concentration inch Fabric inch Rug inch Sheet 200 indicated concentration Insulation Interrelations Between Cement Laminate limits Matte Sheet methyl methacrylate Modacrylic National Bureau Number nylon oz/yd PAPER HONEYCOMB percent Plasticized Polyamide Polyester Polyethylene terephthalate polysulfone polytetrafluoroethylene Polyvinyl Polyvinyl acetate Polyvinyl chloride Polyvinyl fluoride possible PVC precleaning layer sample Seat panels smoke accumulation smoke chamber Smoke D Smoke Measurements smoke particles smoke test chamber smoldering exposures specific ion electrode specific optical density surface area temperature terials thickness toxicological tration Typical smoke urethane urethane foam vinyl chloride volume wool
Popular passages
Page 1 - Measurements are reported of the smoke produced during both flaming and smoldering exposures on 141 aircraft interior materials. Smoke is reported in terms of specific optical density, a dimensionless attenuation coefficient which defines the photometric obscuration produced by a quantity of smoke accumulated from a specimen of given thickness and unit surface area within a chamber of unit volume. A very wide range in the maximum specific optical density was observed. For the majority of materials,...