Smoke and Gases Produced by Burning Aircraft Interior MaterialsU.S. Government Printing Office, 1969 - 27 pages |
From inside the book
Results 1-5 of 8
Page
... Test results and analysis .. 3.1 . Material identification 3.2 . Smoke measurements . 3.3 . Gas analysis . __ 4. Discussion . 5. Conclusions . 6. References 7. Appendix 1. Gas analysis . 7.1 . Colorimetric indicator tubes 7.2 . Specific ...
... Test results and analysis .. 3.1 . Material identification 3.2 . Smoke measurements . 3.3 . Gas analysis . __ 4. Discussion . 5. Conclusions . 6. References 7. Appendix 1. Gas analysis . 7.1 . Colorimetric indicator tubes 7.2 . Specific ...
Page 3
... detector tubes and by specific ion electrode are presented in appendix 1 . Indicator tubes were used to detect CO , HCN , HCI , HF , SO2 , NO + NO2 , NH3 , Cl2 and COCl2 , since these gases have generally been considered toxicologically ...
... detector tubes and by specific ion electrode are presented in appendix 1 . Indicator tubes were used to detect CO , HCN , HCI , HF , SO2 , NO + NO2 , NH3 , Cl2 and COCl2 , since these gases have generally been considered toxicologically ...
Page 9
... tube inlet generally ranged from 46 to 52 ° C ( 115 to 126 ° F ) , the higher temperatures occurring during flaming tests on heavier materials . Due to the cooling effect of the precleaning layers of the indicator tubes , the ...
... tube inlet generally ranged from 46 to 52 ° C ( 115 to 126 ° F ) , the higher temperatures occurring during flaming tests on heavier materials . Due to the cooling effect of the precleaning layers of the indicator tubes , the ...
Page 11
... tubes ; however , these are suitable only where interferences by other gases are absent , and where pre- cision is not of primary importance . The ... Indicator Tubes The manufacturer provided general information 11 Conclusions References.
... tubes ; however , these are suitable only where interferences by other gases are absent , and where pre- cision is not of primary importance . The ... Indicator Tubes The manufacturer provided general information 11 Conclusions References.
Page 12
... Measuring range of colorimetric indicator tubes and toxicological data for selected gases Henderson , Y. , Haggard , H. W .: Noxious Gases . ( Reinhold Publishing Corp. , New York 1943 ) . Elkins , H. B .: The Chemistry of Industrial ...
... Measuring range of colorimetric indicator tubes and toxicological data for selected gases Henderson , Y. , Haggard , H. W .: Noxious Gases . ( Reinhold Publishing Corp. , New York 1943 ) . Elkins , H. B .: The Chemistry of Industrial ...
Common terms and phrases
400 Maximum Smoke acetate adsorption Aircraft Interior Materials appendix asbestos Building Science Series calibration cents CHLOROPRENE cm³ cm³/min colorimetric indicator tubes colorimetric tubes components concen copolymer D₁ density of 16 density of smoke dilution Exposure Value Fabric UC film flaming and smoldering ft² gas concentrations gas detector tubes gaseous products gases Glass fiber HCl concentration inch Fabric inch Rug inch Sheet 200 indicated concentration Insulation Interrelations Between Cement Laminate limits Matte Sheet methyl methacrylate Modacrylic National Bureau Number nylon oz/yd PAPER HONEYCOMB percent Plasticized Polyamide Polyester Polyethylene terephthalate polysulfone polytetrafluoroethylene Polyvinyl Polyvinyl acetate Polyvinyl chloride Polyvinyl fluoride possible PVC precleaning layer sample Seat panels smoke accumulation smoke chamber Smoke D Smoke Measurements smoke particles smoke test chamber smoldering exposures specific ion electrode specific optical density surface area temperature terials thickness toxicological tration Typical smoke urethane urethane foam vinyl chloride volume wool
Popular passages
Page 1 - Measurements are reported of the smoke produced during both flaming and smoldering exposures on 141 aircraft interior materials. Smoke is reported in terms of specific optical density, a dimensionless attenuation coefficient which defines the photometric obscuration produced by a quantity of smoke accumulated from a specimen of given thickness and unit surface area within a chamber of unit volume. A very wide range in the maximum specific optical density was observed. For the majority of materials,...