Smoke and Gases Produced by Burning Aircraft Interior MaterialsU.S. Government Printing Office, 1969 - 27 pages |
From inside the book
Results 1-5 of 7
Page 5
... Concentration , Max . Indication , ppm + Max . Indicated Concentrations of HF is Shown in HC1 Column Where Latter was not Detected Chloroprene 82 131 Chlorosulfonated PE 83 130 Silicone Rubber 63. 14 14 3,58 149 157 63 2 Modacrylic 132 ...
... Concentration , Max . Indication , ppm + Max . Indicated Concentrations of HF is Shown in HC1 Column Where Latter was not Detected Chloroprene 82 131 Chlorosulfonated PE 83 130 Silicone Rubber 63. 14 14 3,58 149 157 63 2 Modacrylic 132 ...
Page 6
... Concentration , Max . Indication , ppm 600 500 1000 CO 200 400 FIGURE 6. Smoke and gas concentrations for individual ... Indicated Concentrations of HF and SO2are Shown in HC1 or HCN Columns Where the Latter were not Detected 1 oz / y3 ...
... Concentration , Max . Indication , ppm 600 500 1000 CO 200 400 FIGURE 6. Smoke and gas concentrations for individual ... Indicated Concentrations of HF and SO2are Shown in HC1 or HCN Columns Where the Latter were not Detected 1 oz / y3 ...
Page 7
... Indicate Values in Excess of Scale Values + Max . Indicated Concentration of S02 is Shown in HCN Column Where Latter was not Detected 1 oz / yd 3.39 x 101 8 / cm FIGURE 7. Smoke and gas concentrations for individual materials ...
... Indicate Values in Excess of Scale Values + Max . Indicated Concentration of S02 is Shown in HCN Column Where Latter was not Detected 1 oz / yd 3.39 x 101 8 / cm FIGURE 7. Smoke and gas concentrations for individual materials ...
Page 8
... Indicated Gas Concentration , ppm HC1 CO 50 HC1 HCN 3 min 4 min 6 min 8 min 60 15 60 13 60 11 60 10 60 10 200 70 85 ... indicated concentrations of gases are listed in appendix 3 along with the smoke data . These values are based on the ...
... Indicated Gas Concentration , ppm HC1 CO 50 HC1 HCN 3 min 4 min 6 min 8 min 60 15 60 13 60 11 60 10 60 10 200 70 85 ... indicated concentrations of gases are listed in appendix 3 along with the smoke data . These values are based on the ...
Page 10
... indicated concentration in smoke test chamber . inhaled smoke particles , or to hysteria or associ- ated physiological or psychological factors . The indicated concentrations of gaseous prod- ucts listed in appendix 3 represent values ...
... indicated concentration in smoke test chamber . inhaled smoke particles , or to hysteria or associ- ated physiological or psychological factors . The indicated concentrations of gaseous prod- ucts listed in appendix 3 represent values ...
Common terms and phrases
400 Maximum Smoke acetate adsorption Aircraft Interior Materials appendix asbestos Building Science Series calibration cents CHLOROPRENE cm³ cm³/min colorimetric indicator tubes colorimetric tubes components concen copolymer D₁ density of 16 density of smoke dilution Exposure Value Fabric UC film flaming and smoldering ft² gas concentrations gas detector tubes gaseous products gases Glass fiber HCl concentration inch Fabric inch Rug inch Sheet 200 indicated concentration Insulation Interrelations Between Cement Laminate limits Matte Sheet methyl methacrylate Modacrylic National Bureau Number nylon oz/yd PAPER HONEYCOMB percent Plasticized Polyamide Polyester Polyethylene terephthalate polysulfone polytetrafluoroethylene Polyvinyl Polyvinyl acetate Polyvinyl chloride Polyvinyl fluoride possible PVC precleaning layer sample Seat panels smoke accumulation smoke chamber Smoke D Smoke Measurements smoke particles smoke test chamber smoldering exposures specific ion electrode specific optical density surface area temperature terials thickness toxicological tration Typical smoke urethane urethane foam vinyl chloride volume wool
Popular passages
Page 1 - Measurements are reported of the smoke produced during both flaming and smoldering exposures on 141 aircraft interior materials. Smoke is reported in terms of specific optical density, a dimensionless attenuation coefficient which defines the photometric obscuration produced by a quantity of smoke accumulated from a specimen of given thickness and unit surface area within a chamber of unit volume. A very wide range in the maximum specific optical density was observed. For the majority of materials,...