... thoroughly to clean a complete change of air equal to the cubic contents of the building every twenty minutes . All piping to be of copper or of brass , standard iron - pipe sizes . Spray heads shall be of brass . Top , sides and ...
... thoroughly to clean a complete change of air equal to the cubic contents of the building every twenty minutes . All piping to be of copper or of brass , standard iron - pipe sizes . Spray heads shall be of brass . Top , sides and ...
Page 276
... thoroughly settle all such excavations and shall dispose of the surplus earth where directed . He shall also repair , to the satisfaction of the City authorities , any damage to sidewalk or street surfaces caused by him in the ...
... thoroughly settle all such excavations and shall dispose of the surplus earth where directed . He shall also repair , to the satisfaction of the City authorities , any damage to sidewalk or street surfaces caused by him in the ...
Page 281
... thoroughly key the burlap to the felt . The floor covering shall then immediately be rolled thoroughly with a roller , to smooth out any air blisters and to secure proper adhesion . The roller shall be made of independently weighted ...
... thoroughly key the burlap to the felt . The floor covering shall then immediately be rolled thoroughly with a roller , to smooth out any air blisters and to secure proper adhesion . The roller shall be made of independently weighted ...
Contents
Chapter II Design | 28 |
Fullsize Details and Shop | 36 |
Prevention of Damage from | 42 |
10 other sections not shown
Common terms and phrases
approved Architect asphalt base basement bidder Board bond brass brick cabinet ceiling cement charging desk clean coat color complete concrete condition construction contract Contractor cork cork carpet corporation cost creosote oil doors drawings edges electric equipment exterior fastened feet finish fixtures flanged floor covering furnace Furnish and install furniture gate valve glass hardware heating holes inches inches high inches wide indicated iron joints joist less Librarian linoleum linseed oil marble masonry material metal mortar mortise and tenon necessary operation Owner paint panel Paragraph Subject Paris green permit pipe plaster Plate plumbing Portland cement proper proposal putty quarter-sawn reading rooms roof samples sand sash Section secure shelf shop drawings shown space specifications square stack steel submitted surface termites terra cotta terrazzo thoroly thru tile tion valve varnish vent wall shelving waterproofing wood wood block workmanship wrought iron