Public Library Buildings: Their Financing, Design, Construction, Equipment and OperationMary O. McComb, 1935 - 325 pages |
From inside the book
Results 1-3 of 49
Page 30
... thick beds , always dry , Clay on thick beds , moderately dry , Clay , soft , Gravel and coarse and , well - cemented , Sand , compact , well - cemented , Sand , clean , dry , Quicksand , alluvial soil , etc. , BEARING POWER , TONS PER ...
... thick beds , always dry , Clay on thick beds , moderately dry , Clay , soft , Gravel and coarse and , well - cemented , Sand , compact , well - cemented , Sand , clean , dry , Quicksand , alluvial soil , etc. , BEARING POWER , TONS PER ...
Page 241
... thickness approximately 1⁄2 inch in thickness , of insulating material approved by the Architect . Neatly joint deadening ... thick . No grounds to be less than 14 inch wide . Set grounds straight and plumb over one another and square at ...
... thickness approximately 1⁄2 inch in thickness , of insulating material approved by the Architect . Neatly joint deadening ... thick . No grounds to be less than 14 inch wide . Set grounds straight and plumb over one another and square at ...
Page 298
... thickness . The battleship linoleum top shall be set in flush with the edge of oak banding . Charging desk top shall be not less than 144 inches in thick- ness at any point . When behind the charging desk facing front , the left rear ...
... thickness . The battleship linoleum top shall be set in flush with the edge of oak banding . Charging desk top shall be not less than 144 inches in thick- ness at any point . When behind the charging desk facing front , the left rear ...
Common terms and phrases
amount appearance applied approved Architect base bidder Board bond brick building cement CHAIRS changes charging City clean coat color complete concrete condition connection construction contract contractor cost covered desk detail direct doors drawings effect electric employees Engineer entire equal equipment expense face feet finish fitted fixtures floor force furnish furniture glass ground heating holes inches included indicated installation iron issue joints keep least less Librarian Library light manner manufacturer material metal method necessary operation owner paint Paragraph pipe plans plaster Plate polished possible prepared prevent proper proposal purchase removed roof ROOM sand secure shelving showing shown side space specifications square stacks standard steel structure Subject submitted supply surface termites tests thick thoroly thru tile tion wall wood