Circular of the National Bureau of Standards, Issue 440U.S. Government Printing Office, 1942 |
From inside the book
Results 1-5 of 100
Page 77
... flasks on instruments standardized for use with the Mohr flask . In addition , 17.5 ° C is well below the temperature of the average laboratory . Because of these and other considerations , the International Commission for Uniform ...
... flasks on instruments standardized for use with the Mohr flask . In addition , 17.5 ° C is well below the temperature of the average laboratory . Because of these and other considerations , the International Commission for Uniform ...
Page 93
... flask , and in the length of the tube used . Some of these act in opposite directions and thus partially cancel or ... flasks , tubes , etc. , having been originally calibrated at 20 ° C but used at some other temperature between 20 ...
... flask , and in the length of the tube used . Some of these act in opposite directions and thus partially cancel or ... flasks , tubes , etc. , having been originally calibrated at 20 ° C but used at some other temperature between 20 ...
Page 106
... flasks should be thoroughly annealed before being graduated . ( 2 ) DESIGN . The cross section of the neck must be circular , and the shape of the flask must be such as to admit of complete emptying * See test fee schedule 423 , p . 553 ...
... flasks should be thoroughly annealed before being graduated . ( 2 ) DESIGN . The cross section of the neck must be circular , and the shape of the flask must be such as to admit of complete emptying * See test fee schedule 423 , p . 553 ...
Page 107
... flasks ) . At the graduation mark the inside diameters of the neck of the flask must be within the limits given in table 9 . TABLE 9. - Diameters of necks and tolerances for volumetric flasks Capacity of flask up to and Diameter of neck ...
... flasks ) . At the graduation mark the inside diameters of the neck of the flask must be within the limits given in table 9 . TABLE 9. - Diameters of necks and tolerances for volumetric flasks Capacity of flask up to and Diameter of neck ...
Page 108
... flask , above the graduation mark . ( 2 ) SUGAR - TESTING FLASK ( BATES ) . The type of flask used in the sugar laboratories of this Bureau and in the United States Customs Service is shown in figure 30 , No. 1. It is especially ...
... flask , above the graduation mark . ( 2 ) SUGAR - TESTING FLASK ( BATES ) . The type of flask used in the sugar laboratories of this Bureau and in the United States Customs Service is shown in figure 30 , No. 1. It is especially ...
Contents
1 | |
2 | |
3 | |
17 | |
18 | |
27 | |
33 | |
41 | |
586 | |
587 | |
588 | |
589 | |
590 | |
591 | |
592 | |
593 | |
47 | |
53 | |
57 | |
64 | |
80 | |
90 | |
115 | |
145 | |
152 | |
164 | |
165 | |
192 | |
199 | |
201 | |
208 | |
212 | |
217 | |
223 | |
232 | |
241 | |
259 | |
262 | |
272 | |
279 | |
284 | |
293 | |
295 | |
300 | |
311 | |
312 | |
316 | |
324 | |
326 | |
336 | |
349 | |
368 | |
374 | |
384 | |
390 | |
398 | |
405 | |
406 | |
411 | |
435 | |
445 | |
455 | |
482 | |
483 | |
513 | |
535 | |
541 | |
543 | |
546 | |
551 | |
562 | |
563 | |
564 | |
576 | |
584 | |
594 | |
596 | |
597 | |
599 | |
601 | |
602 | |
603 | |
604 | |
605 | |
606 | |
607 | |
608 | |
609 | |
610 | |
612 | |
613 | |
614 | |
624 | |
625 | |
627 | |
632 | |
642 | |
643 | |
644 | |
647 | |
648 | |
650 | |
652 | |
657 | |
658 | |
662 | |
663 | |
664 | |
666 | |
670 | |
671 | |
672 | |
673 | |
674 | |
676 | |
677 | |
679 | |
680 | |
683 | |
690 | |
691 | |
692 | |
694 | |
696 | |
702 | |
703 | |
704 | |
762 | |
766 | |
767 | |
781 | |
800 | |
810 | |
Other editions - View all
Common terms and phrases
acetate added alpha amount analysis analyzer apparatus aqueous azimuth beaker beam beta boiling Brix Bureau of Standards calcium calculated cell CH₂OH Chem chloride coefficient color components concentration configuration constant containing cooled copper correction crystalline crystals decolorizing carbon determined deut dextrose dilute direction dissolved distilled electrode equation equilibrium evaporated FIGURE filter filtrate flask galactose glass glycosides grams HCOH heating hydrochloric acid hydrogen hydrolysis instrument invert sugar invertase Isbell lactose lamp levulose liquid measurements mercury method methyl alcohol mixture modifications molasses mutarotation nicol nicol prism normal weight obtained optical rotation oscillation oxide percent plane polarized polariscope polarized light potassium precipitate prism procedure pyranose quantity quartz quartz control plates raffinose reaction reducing sugars refracting saccharimeter sample sirup sodium sodium hydroxide solubility specific rotation sucrose sugar solution sulfate sulfuric acid temperature thickness tion titration tube turbidity vacuo volume washed wave length
Popular passages
Page 382 - NOTE. — For the purpose of interpreting these specifications the following definitions apply: The total length is the over-all length of the finished instrument. The diameter is that measured with a ring gage. The length of the bulb is the distance from the bottom of the bulb to the beginning of the enamel backing. The top of the thermometer is the top of the finished instrument.
Page 158 - If the analyst is in doubt as to the completion of the hydrolysis, allow a portion of the solution to remain for several hours and again polarize. If there is no change from the previous reading, the inversion is complete, and the reading and temperature of the solution should be carefully noted.
Page 181 - Titrate at once with the thiosulphate solution until the brown tinge has become weak, then add sufficient starch liquor to produce a marked blue coloration. Continue the titration cautiously until the color due to free iodin has entirely vanished.
Page 768 - ... to test the correctness of saccharimeters ; for those who execute commercial analyses, the repeated control of the instruments is to be accomplished, now as before, by quartz plates. 4. In effecting the polarization of substances containing sugar, half-shade instruments, or triple field, only are to be employed.
Page 177 - By consulting the table it will be seen that the vertical column headed 150 is nearest to Z, 145, and the horizontal column headed 95 : 5 is nearest to the ratio of R to I, 95.1 : 4.9.
Page 782 - ... not imported to be commercially used for the extraction of sugar, or for human consumption...
Page 776 - After bringing the solution exactly to the mark at the proper temperature, and after wiping out the neck of the flask with filter paper, pour all of the wellshaken clarified sugar solution on a rapidly acting filter. Reject the first portions of the filtrate and use the rest, which must be perfectly clear for polarization.
Page 667 - If the number is less than 1, make the characteristic of the logarithm negative, and one unit more than the number of zeros between the decimal point and the first significant figure of the given number.
Page 789 - ... test of the importation and also the quantity and test of each lot from which such average test is obtained.
Page 787 - Receptacles — How sampled. — Sugar in hogsheads and other wooden packages shall be sampled by putting the long trier diagonally through the package from chime to chime, one trierful to constitute a sample, except in small lots, when an equal number of trierfuls shall be taken from each package to furnish the required amount of sugar necessary to make a sufficient sample. In the sampling of baskets, bags, seroons, and mats the short trier shall be used, care being exercised to have each sample...