Code of Federal Regulations: Containing a Codification of Documents of General Applicability and Future Effect as of December 31, 1948, with Ancillaries and IndexDivision of the Federal Register, the National Archives, 1998 Special edition of the Federal Register, containing a codification of documents of general applicability and future effect ... with ancillaries. |
From inside the book
Results 1-5 of 100
Page 25
... percent of the time shall be considered to be centrally fueled for the purpose of this defini- tion . The fact that one or more vehi- cles in a fleet is / are not centrally fueled does not exempt an entire fleet from the program . The ...
... percent of the time shall be considered to be centrally fueled for the purpose of this defini- tion . The fact that one or more vehi- cles in a fleet is / are not centrally fueled does not exempt an entire fleet from the program . The ...
Page 48
... percent during the acceleration mode ; ( 2 ) 15 percent during the lugging mode ; and ( 3 ) 50 percent during the peaks in ei- ther the acceleration or lugging modes . ( b ) Opacity levels are to be measured and calculated as set forth ...
... percent during the acceleration mode ; ( 2 ) 15 percent during the lugging mode ; and ( 3 ) 50 percent during the peaks in ei- ther the acceleration or lugging modes . ( b ) Opacity levels are to be measured and calculated as set forth ...
Page 62
... percent of the calculated torque . ( 8 ) If the measured torque is not within 2 percent of the calculated torque , adjust or repair the system . Re- peat steps in paragraphs ( b ) ( 1 ) through ( b ) ( 6 ) of this section with the ...
... percent of the calculated torque . ( 8 ) If the measured torque is not within 2 percent of the calculated torque , adjust or repair the system . Re- peat steps in paragraphs ( b ) ( 1 ) through ( b ) ( 6 ) of this section with the ...
Page 63
... percent of oxygen inter- ference must be less than 3 percent , as specified in § 89.319-96 ( d ) . ( 5 ) Oxides of nitrogen ( NOx ) analysis . ( i ) This analysis device must consist of the subsequent items , following the sample probe ...
... percent of oxygen inter- ference must be less than 3 percent , as specified in § 89.319-96 ( d ) . ( 5 ) Oxides of nitrogen ( NOx ) analysis . ( i ) This analysis device must consist of the subsequent items , following the sample probe ...
Page 64
... per- cent of full - scale chart deflection should generally not be used . ( 2 ) Some high resolution read - out systems , such as computers , data loggers , and so forth , can provide suffi- cient accuracy and resolution below 15 percent ...
... per- cent of full - scale chart deflection should generally not be used . ( 2 ) Some high resolution read - out systems , such as computers , data loggers , and so forth , can provide suffi- cient accuracy and resolution below 15 percent ...
Other editions - View all
Common terms and phrases
adjustment Adminis Administrator Agency analyzer Appendix applicable approved calculated calibration calibration curve carbon carbon monoxide certificate of conformity Clean Air Act CO₂ comotive compliance comply components concentration credits determined dilute exhaust discharge dynamometer emis emission control emission standards emission test engine family engine manufacturer equipment exemption exhaust emission exhaust gas exhaust sample facility factor Federal flow rate gases gine GVWR hearing HFID hydrocarbon in-use inlet loco locomotive engine locomotive or locomotive maintenance manufac manufacturer or remanufac manufacturer or remanufacturer manufacturer's means measured ment mode NDIR nonconformity nonroad engine owner or operator paragraph performed prior production pump pursuant quired range records regulations request response plan sample probe sion span gas specified submitted subpart temperature test engine test order test procedures tion torque trator turer U.S. Customs Service valve vehicle