NBS Minimal BASIC Test Programs: Version 2, User's Manual, Volume 13 |
From inside the book
Page 46
This group completes the latter two steps . 5.14.1 Standard Capabilities In Context Of LET - statement This test tries out various lengthy expressions , using the full generality allowed by the standard , and assigns the resulting value ...
This group completes the latter two steps . 5.14.1 Standard Capabilities In Context Of LET - statement This test tries out various lengthy expressions , using the full generality allowed by the standard , and assigns the resulting value ...
Page 57
REFS : 11.2 11.4 10.2 10.4 PROGRAM NUMBER 47 INCREMENT IN THE STEP CLAUSE OF THE FOR - STATEMENT DEFAULTS TO A VALUE OF ONE . REFS : 11.2 11.4 PROGRAM NUMBER 48 LIMIT AND INCREMENT IN THE FOR - STATEMENT ARE EVALUATED ONCE UPON ENTERING ...
REFS : 11.2 11.4 10.2 10.4 PROGRAM NUMBER 47 INCREMENT IN THE STEP CLAUSE OF THE FOR - STATEMENT DEFAULTS TO A VALUE OF ONE . REFS : 11.2 11.4 PROGRAM NUMBER 48 LIMIT AND INCREMENT IN THE FOR - STATEMENT ARE EVALUATED ONCE UPON ENTERING ...
Page 138
2080 PRINT " END PROGRAM 44 " 2090 STOP 3000 REM SUBROUTINE TO TEST VARIOUS VALUES IN THE FOR - LOOP 3010 PRINT 3020 PRINT " LOOP IS : FOR I1 = " ; A1 ; " TO " ; B1 ; " STEP " C1 3030 PRINT 3040 PRINT " CONTROL VARIABLE : " 3050 PRINT ...
2080 PRINT " END PROGRAM 44 " 2090 STOP 3000 REM SUBROUTINE TO TEST VARIOUS VALUES IN THE FOR - LOOP 3010 PRINT 3020 PRINT " LOOP IS : FOR I1 = " ; A1 ; " TO " ; B1 ; " STEP " C1 3030 PRINT 3040 PRINT " CONTROL VARIABLE : " 3050 PRINT ...
Page 139
TO PASS THE TEST , THE CONTROL - VARIABLE MUST TAKE ON THE APPROPRIATE VALUES AND THE LOOP MUST BE EXECUTED THE CORRECT NUMBER OF TIMES . BEGIN TEST . LOOP IS : FOR I1 = 9.87789E - 2 ΤΟ 9.87800E - 2 STEP 3.00000E - 7 CONTROL VARIABLE ...
TO PASS THE TEST , THE CONTROL - VARIABLE MUST TAKE ON THE APPROPRIATE VALUES AND THE LOOP MUST BE EXECUTED THE CORRECT NUMBER OF TIMES . BEGIN TEST . LOOP IS : FOR I1 = 9.87789E - 2 ΤΟ 9.87800E - 2 STEP 3.00000E - 7 CONTROL VARIABLE ...
Page 140
TIMES THROUGH LOOP : SHOULD BE : 0 ACTUAL : 0 RESULT : OK LOOP IS : FOR I1 = 8 TO 5 STEP 1 CONTROL VARIABLE : SHOULD BE LOOP EXITED 8 ACTUAL 8 NO . TIMES THROUGH LOOP : SHOULD BE : 0 RESULT OK ACTUAL : O RESULT : OK LOOP IS : FOR I1 = 8 ...
TIMES THROUGH LOOP : SHOULD BE : 0 ACTUAL : 0 RESULT : OK LOOP IS : FOR I1 = 8 TO 5 STEP 1 CONTROL VARIABLE : SHOULD BE LOOP EXITED 8 ACTUAL 8 NO . TIMES THROUGH LOOP : SHOULD BE : 0 RESULT OK ACTUAL : O RESULT : OK LOOP IS : FOR I1 = 8 ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Other editions - View all
Common terms and phrases
20 PRINT 40 PRINT SECTION ACCEPT THE PROGRAM ACCOMPANIED BY DOCUMENTATION ACCURACY ACTUAL ALLOWING ANSI STANDARD ARGUMENT ARRAY ASSIGNED BASIC TEST PROGRAMS CHARACTERS COLUMN COMPUTED CONSTANTS CONTAINING CONTROL DATA DIGITS DISPLAYED END END TEST ENTER ERROR EVALUATION EXACT EXECUTION EXPECTED FOLLOWING FUNCTION GOSUB GOTO IDENTIFYING THE EXCEPTION implementation INFORMATIVE TEST INPUT INPUT-REPLY ITEM LINE LOOP MEASURE MESSAGE IDENTIFYING MINIMAL BASIC TEST NBS MINIMAL BASIC NEGATIVE NON-STANDARD FEATURE NOTE NUMERIC EXPRESSIONS OCCUR OK OK OK operations ORDER OUTPUT OVERFLOW PASS THIS TEST POSITIVE PRINT 40 PRINT PRINT BEGIN TEST PRINT END PROGRAM PRINT END TEST PRINT PROGRAM FILE PRINT THIS SECTION PRINT TO PASS PROCESSOR PROGRAM NUMBER PROGRAM TESTS PROGRAMS USER'S MANUAL READ REFERENCE REFS REJECT THE PROGRAM REPORTED RESULT RETURN RND FUNCTION SECTION TESTS SPACE STATEMENT STEP STRING SUBSCRIPT SUPPLIED TERMINATE TEST FAILED TEST OK TEST PASSED TYPE UNDERFLOW VALUE VARIABLE ZERO