NBS Minimal BASIC Test Programs: Version 2, User's Manual, Volume 2U.S. Department of Commerce, National Bureau of Standards, 1980 |
From inside the book
Results 1-5 of 45
Page 46
... steps . 5.14.1 Standard Capabilities In Context Of LET - statement This test tries out various lengthy expressions , using the the even full generality allowed by the standard , and assigns resulting value to a variable . As usual , if ...
... steps . 5.14.1 Standard Capabilities In Context Of LET - statement This test tries out various lengthy expressions , using the the even full generality allowed by the standard , and assigns resulting value to a variable . As usual , if ...
Page 57
... STEP CLAUSE OF THE FOR - STATEMENT DEFAULTS TO A VALUE OF ONE . REFS : 11.2 11.4 PROGRAM NUMBER 48 LIMIT AND INCREMENT IN THE FOR - STATEMENT ARE EVALUATED ONCE UPON ENTERING THE LOOP . REFS : 11.2 11.4 PROGRAM NUMBER 49 NESTED FOR ...
... STEP CLAUSE OF THE FOR - STATEMENT DEFAULTS TO A VALUE OF ONE . REFS : 11.2 11.4 PROGRAM NUMBER 48 LIMIT AND INCREMENT IN THE FOR - STATEMENT ARE EVALUATED ONCE UPON ENTERING THE LOOP . REFS : 11.2 11.4 PROGRAM NUMBER 49 NESTED FOR ...
Page 138
... STEP " ; C1 3030 PRINT 3040 PRINT " CONTROL VARIABLE : " 3050 PRINT " SHOULD BE " , " ACTUAL " , " RESULT " 3060 LET A2 = A1 3070 LET B2 = B1 3080 LET C2 = C1 3090 LET 12 = A2 3100 REM S1 IS ERROR SWITCH 3110 LET S1 = 0 3120 REM T1 IS ...
... STEP " ; C1 3030 PRINT 3040 PRINT " CONTROL VARIABLE : " 3050 PRINT " SHOULD BE " , " ACTUAL " , " RESULT " 3060 LET A2 = A1 3070 LET B2 = B1 3080 LET C2 = C1 3090 LET 12 = A2 3100 REM S1 IS ERROR SWITCH 3110 LET S1 = 0 3120 REM T1 IS ...
Page 139
... STEP 3.00000E - 7 CONTROL VARIABLE : SHOULD BE ACTUAL RESULT 9.87789E - 2 9.87789E - 2 OK 9.87792E - 2 9.87792E - 2 OK 9.87795E - 2 9.87795E - 2 OK 9.87798E - 2 9.87798E - 2 OK LOOP EXITED 9.87801E - 2 9.87801E - 2 OK NO . TIMES THROUGH ...
... STEP 3.00000E - 7 CONTROL VARIABLE : SHOULD BE ACTUAL RESULT 9.87789E - 2 9.87789E - 2 OK 9.87792E - 2 9.87792E - 2 OK 9.87795E - 2 9.87795E - 2 OK 9.87798E - 2 9.87798E - 2 OK LOOP EXITED 9.87801E - 2 9.87801E - 2 OK NO . TIMES THROUGH ...
Page 140
... STEP 1 CONTROL VARIABLE : SHOULD BE ACTUAL LOOP EXITED 8 8 NO . TIMES THROUGH LOOP : SHOULD BE : 0 RESULT OK ACTUAL : 0 RESULT : OK LOOP IS : FOR I1 = 8 TO -5 STEP -3 CONTROL VARIABLE : SHOULD BE ACTUAL RESULT 8 8 OK 5 5 OK 2 2 OK -1 ...
... STEP 1 CONTROL VARIABLE : SHOULD BE ACTUAL LOOP EXITED 8 8 NO . TIMES THROUGH LOOP : SHOULD BE : 0 RESULT OK ACTUAL : 0 RESULT : OK LOOP IS : FOR I1 = 8 TO -5 STEP -3 CONTROL VARIABLE : SHOULD BE ACTUAL RESULT 8 8 OK 5 5 OK 2 2 OK -1 ...
Other editions - View all
Common terms and phrases
15 PRINT 20 PRINT 40 PRINT SECTION ACCEPT THE PROGRAM ACCOMPANIED BY DOCUMENTATION ACCURATELY DESCRIBING ANSI STANDARD 7.2 APPROPRIATE ERROR MESSAGE ARGUMENT BASIC TEST PROGRAMS COMPUTED DATA DESCRIBING THE FEATURE'S DETAILED CRITERIA DIM-STATEMENT DISPLAYED DIVISION BY ZERO END END TEST END PROGRAM FILE END TEST END EXRAD FEATURE OF MINIMAL FEATURE'S INTERPRETATION FOR-STATEMENT GOSUB GOTO IDENTIFYING THE EXCEPTION implementation INPUT INPUT-REPLY LINE NUMBER MACHINE INFINITY MESSAGE IDENTIFYING MINIMAL BASIC TEST NBS MINIMAL BASIC NON-STANDARD FEATURE NUMERIC EXPRESSIONS OK EXITING FOR-BLOCK ON-GOTO OPTION BASE PASS THIS TEST PRINT 11 PRINT 40 PRINT PRINT BEGIN TEST PRINT END PROGRAM PRINT END TEST PRINT FOR DETAILED PRINT PROGRAM FILE PRINT THIS PROGRAM PRINT THIS SECTION PRINT TO PASS PROCESSOR PROGRAM NUMBER PROGRAM TESTS PROGRAMS USER'S MANUAL QUOTED STRINGS REFS REJECT THE PROGRAM REM SUBROUTINE RND FUNCTION SECTION TESTS SIGNIFICAND STATEMENT TEST FAILED TEST IS INFORMATIVE TEST OK TEST PROGRAMS USER'S UNDERFLOW