NBS Minimal BASIC Test Programs: Version 2, User's Manual, Volume 13U.S. Department of Commerce, National Bureau of Standards, 1980 |
From inside the book
Results 1-5 of 59
Page 43
... negative values a descending sequence . 5.12.3 RND And RANDOMIZE to Unlike the other functions , there is no single correct value returned by any individual reference to RND , but only the properties of an aggregation of returned values ...
... negative values a descending sequence . 5.12.3 RND And RANDOMIZE to Unlike the other functions , there is no single correct value returned by any individual reference to RND , but only the properties of an aggregation of returned values ...
Page 56
... NEGATIVE POWER . 7.5 PROGRAM NUMBER 32 EXCEPTION REFS : - 7.5 NEGATIVE QUANTITY RAISED TO A NON - INTEGRAL POWER . PROGRAM NUMBER 33 EXCEPTION UNDERFLOW OF NUMERIC EXPRESSIONS . - REFS : 7.4 UNDERFLOW OF NUMERIC CONSTANTS . PROGRAM ...
... NEGATIVE POWER . 7.5 PROGRAM NUMBER 32 EXCEPTION REFS : - 7.5 NEGATIVE QUANTITY RAISED TO A NON - INTEGRAL POWER . PROGRAM NUMBER 33 EXCEPTION UNDERFLOW OF NUMERIC EXPRESSIONS . - REFS : 7.4 UNDERFLOW OF NUMERIC CONSTANTS . PROGRAM ...
Page 63
... NEGATIVE ARGUMENT . REFS : 8.5 PROGRAM NUMBER 119 ACCURACY OF ATN FUNCTION . REFS : 7.6 8.4 PROGRAM NUMBER 120 ACCURACY OF COS FUNCTION . REFS : 7.6 8.4 PROGRAM NUMBER 121 ACCURACY OF EXP FUNCTION . REFS : 7.6 8.4 PROGRAM NUMBER 122 ...
... NEGATIVE ARGUMENT . REFS : 8.5 PROGRAM NUMBER 119 ACCURACY OF ATN FUNCTION . REFS : 7.6 8.4 PROGRAM NUMBER 120 ACCURACY OF COS FUNCTION . REFS : 7.6 8.4 PROGRAM NUMBER 121 ACCURACY OF EXP FUNCTION . REFS : 7.6 8.4 PROGRAM NUMBER 122 ...
Page 67
... NEGATIVE QUANTITY RAISED TO A NON - INTEGRAL POWER IN A SUBSCRIPT . REFS : 7.5 6.2 PROGRAM NUMBER 171 EXCEPTION REFS : 8.5 - LOG OF A NEGATIVE QUANTITY IN AN ARGUMENT . 16.2 PROGRAM NUMBER EXCEPTION - 172 SQR OF NEGATIVE QUANTITY IN ...
... NEGATIVE QUANTITY RAISED TO A NON - INTEGRAL POWER IN A SUBSCRIPT . REFS : 7.5 6.2 PROGRAM NUMBER 171 EXCEPTION REFS : 8.5 - LOG OF A NEGATIVE QUANTITY IN AN ARGUMENT . 16.2 PROGRAM NUMBER EXCEPTION - 172 SQR OF NEGATIVE QUANTITY IN ...
Page 68
... NEGATIVE QUANTITY RAISED TO A NON - INTEGRAL POWER IN FOR - STATEMENT . REFS : 7.5 11.2 PROGRAM NUMBER 183 EXCEPTION - EVALUATION OF NUMERIC EXPRESSIONS IN THE FOR - STATEMENT . REFS : 7.5 11.2 PROGRAM NUMBER 184 EXCEPTION - UNDERFLOW ...
... NEGATIVE QUANTITY RAISED TO A NON - INTEGRAL POWER IN FOR - STATEMENT . REFS : 7.5 11.2 PROGRAM NUMBER 183 EXCEPTION - EVALUATION OF NUMERIC EXPRESSIONS IN THE FOR - STATEMENT . REFS : 7.5 11.2 PROGRAM NUMBER 184 EXCEPTION - UNDERFLOW ...
Other editions - View all
Common terms and phrases
20 PRINT 40 PRINT SECTION ACCEPT THE PROGRAM ACCOMPANIED BY DOCUMENTATION ACCURACY ACTUAL ALLOWING ANSI STANDARD ARGUMENT ARRAY ASSIGNED BASIC TEST PROGRAMS CHARACTERS COLUMN COMPUTED CONSTANTS CONTAINING CONTROL DATA DIGITS DISPLAYED END END TEST ENTER ERROR EVALUATION EXACT EXECUTION EXPECTED FOLLOWING FUNCTION GOSUB GOTO IDENTIFYING THE EXCEPTION implementation INFORMATIVE TEST INPUT INPUT-REPLY ITEM LINE LOOP MEASURE MESSAGE IDENTIFYING MINIMAL BASIC TEST NBS MINIMAL BASIC NEGATIVE NON-STANDARD FEATURE NOTE NUMERIC EXPRESSIONS OCCUR OK OK OK operations ORDER OUTPUT OVERFLOW PASS THIS TEST POSITIVE PRINT 40 PRINT PRINT BEGIN TEST PRINT END PROGRAM PRINT END TEST PRINT PROGRAM FILE PRINT THIS SECTION PRINT TO PASS PROCESSOR PROGRAM NUMBER PROGRAM TESTS PROGRAMS USER'S MANUAL READ REFERENCE REFS REJECT THE PROGRAM REPORTED RESULT RETURN RND FUNCTION SECTION TESTS SPACE STATEMENT STEP STRING SUBSCRIPT SUPPLIED TERMINATE TEST FAILED TEST OK TEST PASSED TYPE UNDERFLOW VALUE VARIABLE ZERO