NBS Minimal BASIC Test Programs: Version 2, User's Manual, Volume 13U.S. Department of Commerce, National Bureau of Standards, 1980 |
From inside the book
Results 1-5 of 59
Page 43
... negative values a descending sequence . 5.12.3 RND And RANDOMIZE Unlike the other functions , there is no single correct value to be returned by any individual reference to RND , but only the properties of an aggregation of returned ...
... negative values a descending sequence . 5.12.3 RND And RANDOMIZE Unlike the other functions , there is no single correct value to be returned by any individual reference to RND , but only the properties of an aggregation of returned ...
Page 56
... NEGATIVE POWER . 7.5 PROGRAM NUMBER 32 EXCEPTION REFS : - 7.5 NEGATIVE QUANTITY RAISED TO A NON - INTEGRAL POWER . PROGRAM NUMBER 33 EXCEPTION UNDERFLOW OF NUMERIC EXPRESSIONS . - REFS : 7.4 UNDERFLOW OF NUMERIC CONSTANTS . PROGRAM ...
... NEGATIVE POWER . 7.5 PROGRAM NUMBER 32 EXCEPTION REFS : - 7.5 NEGATIVE QUANTITY RAISED TO A NON - INTEGRAL POWER . PROGRAM NUMBER 33 EXCEPTION UNDERFLOW OF NUMERIC EXPRESSIONS . - REFS : 7.4 UNDERFLOW OF NUMERIC CONSTANTS . PROGRAM ...
Page 63
... NEGATIVE ARGUMENT . 8.5 PROGRAM NUMBER 119 ACCURACY OF ATN FUNCTION . REFS : 7.6 8.4 PROGRAM NUMBER 120 ACCURACY OF COS FUNCTION . REFS : 7.6 8.4 PROGRAM NUMBER 121 ACCURACY OF EXP FUNCTION . REFS : 7.6 8.4 PROGRAM NUMBER 122 EXCEPTION ...
... NEGATIVE ARGUMENT . 8.5 PROGRAM NUMBER 119 ACCURACY OF ATN FUNCTION . REFS : 7.6 8.4 PROGRAM NUMBER 120 ACCURACY OF COS FUNCTION . REFS : 7.6 8.4 PROGRAM NUMBER 121 ACCURACY OF EXP FUNCTION . REFS : 7.6 8.4 PROGRAM NUMBER 122 EXCEPTION ...
Page 67
... NEGATIVE QUANTITY RAISED TO A NON - INTEGRAL POWER IN A SUBSCRIPT . REFS : 7.5 6.2 PROGRAM NUMBER 171 EXCEPTION REFS : 8.5 - LOG OF A NEGATIVE QUANTITY IN AN ARGUMENT . 16.2 PROGRAM NUMBER EXCEPTION - 172 SQR OF NEGATIVE QUANTITY IN ...
... NEGATIVE QUANTITY RAISED TO A NON - INTEGRAL POWER IN A SUBSCRIPT . REFS : 7.5 6.2 PROGRAM NUMBER 171 EXCEPTION REFS : 8.5 - LOG OF A NEGATIVE QUANTITY IN AN ARGUMENT . 16.2 PROGRAM NUMBER EXCEPTION - 172 SQR OF NEGATIVE QUANTITY IN ...
Page 68
... NEGATIVE QUANTITY RAISED TO A NON - INTEGRAL POWER IN FOR - STATEMENT . REFS : 7.5 11.2 PROGRAM NUMBER 183 EXCEPTION - EVALUATION OF NUMERIC EXPRESSIONS IN THE FOR - STATEMENT . REFS : 7.5 11.2 PROGRAM NUMBER 184 EXCEPTION - UNDERFLOW ...
... NEGATIVE QUANTITY RAISED TO A NON - INTEGRAL POWER IN FOR - STATEMENT . REFS : 7.5 11.2 PROGRAM NUMBER 183 EXCEPTION - EVALUATION OF NUMERIC EXPRESSIONS IN THE FOR - STATEMENT . REFS : 7.5 11.2 PROGRAM NUMBER 184 EXCEPTION - UNDERFLOW ...
Other editions - View all
Common terms and phrases
15 PRINT 20 PRINT 40 PRINT SECTION ACCEPT THE PROGRAM ACCOMPANIED BY DOCUMENTATION ACCURATELY DESCRIBING ANSI STANDARD 7.2 APPROPRIATE ERROR MESSAGE ARGUMENT ASSIGNED BASIC TEST PROGRAMS COMPUTED DATA DESCRIBING THE FEATURE'S DETAILED CRITERIA DIM-STATEMENT DISPLAYED DIVISION BY ZERO END END TEST END PROGRAM FILE EXRAD FEATURE OF MINIMAL FEATURE'S INTERPRETATION FOR-STATEMENT GOSUB GOTO IDENTIFYING THE EXCEPTION implementation INFORMATIVE TEST PASSED INPUT INPUT-REPLY LINE NUMBER LINE-NUMBERS MACHINE INFINITY MESSAGE IDENTIFYING MINIMAL BASIC TEST NBS MINIMAL BASIC NON-STANDARD FEATURE NUMERIC EXPRESSIONS OK OK OK ON-GOTO OPTION BASE PASS THIS TEST PRINT 40 PRINT PRINT BEGIN TEST PRINT END PROGRAM PRINT END TEST PRINT FOR DETAILED PRINT PROGRAM FILE PRINT THIS PROGRAM PRINT THIS SECTION PRINT TO PASS PROCESSOR PROGRAM TESTS PROGRAMS USER'S MANUAL QUOTED STRINGS READ REFS REJECT THE PROGRAM REM SUBROUTINE RND FUNCTION SECTION TESTS SIGNIFICAND STATEMENT TEST IS INFORMATIVE TEST OK TEST PROGRAMS USER'S UNDERFLOW USER-DEFINED FUNCTION