Special Technical Facilities at the National Bureau of StandardsNational Bureau of Standards, 1976 - 50 pages |
From inside the book
Results 1-5 of 14
Page 8
... determination of the thermal conductivity of dry specimens of good insulators ; its range is 0.1 to 10 Btu per hour ft2 ( ° F / in . ) , or 0.15 to 15 milliwatts per cm ° C from 0 to 130 ° F ( -18 to 54 ° C ) . Recently a new and more ...
... determination of the thermal conductivity of dry specimens of good insulators ; its range is 0.1 to 10 Btu per hour ft2 ( ° F / in . ) , or 0.15 to 15 milliwatts per cm ° C from 0 to 130 ° F ( -18 to 54 ° C ) . Recently a new and more ...
Page 12
... Determination of the amount and prod- ucts of reaction can be determined by measurement of the amount of CO2 gas formed , and by analysis of aqueous solution constituents . Applications : Used to determine enthalpies of reac- tion at or ...
... Determination of the amount and prod- ucts of reaction can be determined by measurement of the amount of CO2 gas formed , and by analysis of aqueous solution constituents . Applications : Used to determine enthalpies of reac- tion at or ...
Page 17
... determination of stacking fault energy as a function of temperature in Ag - Sn and Au - Sn alloys ; analysis of deformation modes in super- plastic Al - base alloys ; study of deformation and corrosion in Cu- , Fe- , and Ni - base ...
... determination of stacking fault energy as a function of temperature in Ag - Sn and Au - Sn alloys ; analysis of deformation modes in super- plastic Al - base alloys ; study of deformation and corrosion in Cu- , Fe- , and Ni - base ...
Page 20
... determinations are made to 300 kbar with an accuracy in the range of 5 percent ; qualitative measurements up to the realiz- able limit of about 500 kbar . Temperature capability to 300 ° C is also available , but the accuracy in the ...
... determinations are made to 300 kbar with an accuracy in the range of 5 percent ; qualitative measurements up to the realiz- able limit of about 500 kbar . Temperature capability to 300 ° C is also available , but the accuracy in the ...
Page 24
... Determination of the pressure of fixed points for " benchmark " purposes ; realization of a standard atmosphere ; calibration of highest quality deadweight gages operating in the range of 1 atmos- phere ; calibration of ultraprecise ...
... Determination of the pressure of fixed points for " benchmark " purposes ; realization of a standard atmosphere ; calibration of highest quality deadweight gages operating in the range of 1 atmos- phere ; calibration of ultraprecise ...
Other editions - View all
Common terms and phrases
accuracy agencies alloys analysis analyzer antenna Applications beam Bureau of Standards calibration calorimeter Capability chemical Chemistry Building Chief cm-¹ Contact controlled Cryogenic crystal detection diameter electrical electron elements energy enthalpies equipment flame flow frequency furnace gases glass heat hygrometers inches instru instrument isotopes laboratory laser liquid Literature machine magnetic mass spectrometer Materials Building measurements ment metals meters Metrology MICROWAVE SPECTROSCOPY molecular Mössbauer Effect National Bureau NBS Reactor NBS research worker NBS staff NBS Tech NBS Technical neutron Nuclear operation optical phase transitions Phone Physics Building Polymer POUND-FORCE pressure programs provides pulse qualified NBS research radiation Ralph Klein RAMAN SPECTROSCOPY range reaction resolution Room rotating sample scanning scientists Section solids spec specimen spectra spectrograph spectroscopy structure studies surface temperature thermal Thermography tion tron UNIVERSAL TESTING MACHINE users Van de Graaff voltage WWWL x-ray