Special Technical Facilities at the National Bureau of StandardsNational Bureau of Standards, 1976 - 50 pages |
From inside the book
Results 1-5 of 16
Page 6
... detection requirements . Applications : Complex reflection ( impedance ) and transmission coefficients of antennas can be meas- ured by making use of the automatic network an- alyzer over the frequency range of 0.1 to 18 GHz . Antennas ...
... detection requirements . Applications : Complex reflection ( impedance ) and transmission coefficients of antennas can be meas- ured by making use of the automatic network an- alyzer over the frequency range of 0.1 to 18 GHz . Antennas ...
Page 9
... Detecting Structural Heat Losses With Mobile Infrared Thermography . Part I , Description of Technique : Nat . Tech . Info . Serv . , U.S. Dept. Comm . , Oct. 1974— NTIS AD / A - 001549 . [ 3 ] ibid - Part II , Survey of Pease Air Force ...
... Detecting Structural Heat Losses With Mobile Infrared Thermography . Part I , Description of Technique : Nat . Tech . Info . Serv . , U.S. Dept. Comm . , Oct. 1974— NTIS AD / A - 001549 . [ 3 ] ibid - Part II , Survey of Pease Air Force ...
Page 10
... detection of small effects of thermal history . Availability : Operation under the direct supervision of Dr. S. S. Chang . Measurements of mutual interest can be arranged with NBS and other government personnel in accord with agreement ...
... detection of small effects of thermal history . Availability : Operation under the direct supervision of Dr. S. S. Chang . Measurements of mutual interest can be arranged with NBS and other government personnel in accord with agreement ...
Page 18
... Detection and calibration unit of CHLORINE FLUX MONI- TOR at left , reagent supply unit at right . CHLORINE FLUX MONITOR This newly developed electrochemical system for measuring traces of chlorine in water is based on the well - known ...
... Detection and calibration unit of CHLORINE FLUX MONI- TOR at left , reagent supply unit at right . CHLORINE FLUX MONITOR This newly developed electrochemical system for measuring traces of chlorine in water is based on the well - known ...
Page 20
... detect shear or longitudinal mode properties are mounted on the outside ; they use a back plate as acoustic buffer . A back plate with one electrical lead is also available . Availability : The equipment is available to qualified ...
... detect shear or longitudinal mode properties are mounted on the outside ; they use a back plate as acoustic buffer . A back plate with one electrical lead is also available . Availability : The equipment is available to qualified ...
Other editions - View all
Common terms and phrases
accuracy agencies alloys analysis analyzer antenna Applications beam Bureau of Standards calibration calorimeter Capability chemical Chemistry Building Chief cm-¹ Contact controlled Cryogenic crystal detection diameter electrical electron elements energy enthalpies equipment flame flow frequency furnace gases glass heat hygrometers inches instru instrument isotopes laboratory laser liquid Literature machine magnetic mass spectrometer Materials Building measurements ment metals meters Metrology MICROWAVE SPECTROSCOPY molecular Mössbauer Effect National Bureau NBS Reactor NBS research worker NBS staff NBS Tech NBS Technical neutron Nuclear operation optical phase transitions Phone Physics Building Polymer POUND-FORCE pressure programs provides pulse qualified NBS research radiation Ralph Klein RAMAN SPECTROSCOPY range reaction resolution Room rotating sample scanning scientists Section solids spec specimen spectra spectrograph spectroscopy structure studies surface temperature thermal Thermography tion tron UNIVERSAL TESTING MACHINE users Van de Graaff voltage WWWL x-ray