Special Technical Facilities at the National Bureau of StandardsNational Bureau of Standards, 1976 - 50 pages |
From inside the book
Results 1-5 of 17
Page
... divisions : Applied Mathematics Electricity Mechanics Heat Sciences Applied Radiation 2 Quantum Electronics & Frequency Laboratory Astrophysics - Cryogenics " . 3 - --- Nuclear Optical Physics Electromagnetics * Time and THE INSTITUTE ...
... divisions : Applied Mathematics Electricity Mechanics Heat Sciences Applied Radiation 2 Quantum Electronics & Frequency Laboratory Astrophysics - Cryogenics " . 3 - --- Nuclear Optical Physics Electromagnetics * Time and THE INSTITUTE ...
Page 2
... Division , Radiation Physics Building , Room C216 , Phone 301- 921-2201 . LINEAR ELECTRON ACCELERATOR ( LINAC ) The linear accelerator ( linac ) facility was designed for maximum flexibility , beam quality , and beam han- dling to ...
... Division , Radiation Physics Building , Room C216 , Phone 301- 921-2201 . LINEAR ELECTRON ACCELERATOR ( LINAC ) The linear accelerator ( linac ) facility was designed for maximum flexibility , beam quality , and beam han- dling to ...
Page 3
... Division , Radiation Physics Building , Room B119 , Phone 301-921-2234 . POSITIVE - ION VAN DE GRAAFF ACCELERATOR , 3 MeV The positive - ion 3 MeV Van de Graaff facility at the National Bureau of Standards has been designed pri- marily ...
... Division , Radiation Physics Building , Room B119 , Phone 301-921-2234 . POSITIVE - ION VAN DE GRAAFF ACCELERATOR , 3 MeV The positive - ion 3 MeV Van de Graaff facility at the National Bureau of Standards has been designed pri- marily ...
Page 5
... Division of the NBS Boulder Laboratories has recently perfected two new and highly accurate methods for determining antenna characteristics from measurements made at greatly reduced distances . The methods are known as the near field ...
... Division of the NBS Boulder Laboratories has recently perfected two new and highly accurate methods for determining antenna characteristics from measurements made at greatly reduced distances . The methods are known as the near field ...
Page 18
... Division , Chemistry Building , Room A225 , Phone 301-921-2883 . PRECISION HUMIDITY MEASUREMENT This facility ... divisions , other Govern- ment agencies , and industrial or scientific laborato- ries . Literature : [ 1 ] J. Res . NBS 40 ...
... Division , Chemistry Building , Room A225 , Phone 301-921-2883 . PRECISION HUMIDITY MEASUREMENT This facility ... divisions , other Govern- ment agencies , and industrial or scientific laborato- ries . Literature : [ 1 ] J. Res . NBS 40 ...
Other editions - View all
Common terms and phrases
accuracy agencies alloys analysis analyzer antenna Applications beam Bureau of Standards calibration calorimeter Capability chemical Chemistry Building Chief cm-¹ Contact controlled Cryogenic crystal detection diameter electrical electron elements energy enthalpies equipment flame flow frequency furnace gases glass heat hygrometers inches instru instrument isotopes laboratory laser liquid Literature machine magnetic mass spectrometer Materials Building measurements ment metals meters Metrology MICROWAVE SPECTROSCOPY molecular Mössbauer Effect National Bureau NBS Reactor NBS research worker NBS staff NBS Tech NBS Technical neutron Nuclear operation optical phase transitions Phone Physics Building Polymer POUND-FORCE pressure programs provides pulse qualified NBS research radiation Ralph Klein RAMAN SPECTROSCOPY range reaction resolution Room rotating sample scanning scientists Section solids spec specimen spectra spectrograph spectroscopy structure studies surface temperature thermal Thermography tion tron UNIVERSAL TESTING MACHINE users Van de Graaff voltage WWWL x-ray