In the actual operation of a steam generator , it is practically impossible to attain optimum protection by passivation through the formation of a thin , compact magnetite layer . When the steam generator is in operation , the thickness ...
In the actual operation of a steam generator , it is practically impossible to attain optimum protection by passivation through the formation of a thin , compact magnetite layer . When the steam generator is in operation , the thickness ...
Page 40
Inhibitors Used for the Acid Cleaning of Steam Generators in the appropriate concentration , is determinant for the success of the operation . In most cases a product is specific for a certain environment and cannot be employed for all ...
Inhibitors Used for the Acid Cleaning of Steam Generators in the appropriate concentration , is determinant for the success of the operation . In most cases a product is specific for a certain environment and cannot be employed for all ...
Page 361
and R. Cytermann 7.2.1 Chemical Cleaning of Internal Surfaces Since water treatment operations are not completely effective , periodic chemical cleaning is required , to prolong the useful life of a boiler / 7,8 / .
and R. Cytermann 7.2.1 Chemical Cleaning of Internal Surfaces Since water treatment operations are not completely effective , periodic chemical cleaning is required , to prolong the useful life of a boiler / 7,8 / .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Electrochemical characterization of some commercial | 36 |
EXPERIMENTAL RESULTS | 44 |
DISCUSSION AND CONCLUSIONS | 51 |
63 other sections not shown
Other editions - View all
Common terms and phrases
acid additional alloy aluminum anodes Antifouling Paints application Association ball behaviour binder boiler Brazil cable calcium carbon carried cent chemical clad cleaning coatings concentration conductors considered construction copper corrosion crack cuprous oxide density determined dispersion dissolution rate effect electrical electrochemical Engineers environments evaluation experimental Figure film fouling galvanized grounding immersion important increase industrial influence inhibitor installed Institute internal layer levels lines materials measurements mechanical metal method mill months necessary obtained Offshore Platforms operation organic oxygen particles performance period pigment plants plate polarization polymer potential Power Stations practical present problems protection recommended removal resinates resistance Review rosin samples sea water Ships shown shows soil solubility solution steel structure surface Table Technology temperature tests toxicant tube units values weight welded zinc