Recently Zaya and Doyle / 13 / reported on the influence of the conductor wire manufacturing process on corrosion performance ; they found that no single fabrication routine conferred improved corrosion resistance to aluminum wires .
Recently Zaya and Doyle / 13 / reported on the influence of the conductor wire manufacturing process on corrosion performance ; they found that no single fabrication routine conferred improved corrosion resistance to aluminum wires .
Page 192
Its use for overhead conductors in high voltage transmission lines has become standard practice practically worldwide , mainly as steel core reinforced cable , but also in the form of alloys with improved mechanical resistance .
Its use for overhead conductors in high voltage transmission lines has become standard practice practically worldwide , mainly as steel core reinforced cable , but also in the form of alloys with improved mechanical resistance .
Page 272
Therefore and improved version of the GALMON method has been envisaged for the near future to be used for the calculation of the polarization resistance as well as the determination of the corrosion current density .
Therefore and improved version of the GALMON method has been envisaged for the near future to be used for the calculation of the polarization resistance as well as the determination of the corrosion current density .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Electrochemical characterization of some commercial | 36 |
EXPERIMENTAL RESULTS | 44 |
DISCUSSION AND CONCLUSIONS | 51 |
63 other sections not shown
Other editions - View all
Common terms and phrases
acid additional alloy aluminum anodes Antifouling Paints application Association ball behaviour binder boiler Brazil cable calcium carbon carried cent chemical clad cleaning coatings concentration conductors considered construction copper corrosion crack cuprous oxide density determined dispersion dissolution rate effect electrical electrochemical Engineers environments evaluation experimental Figure film fouling galvanized grounding immersion important increase industrial influence inhibitor installed Institute internal layer levels lines materials measurements mechanical metal method mill months necessary obtained Offshore Platforms operation organic oxygen particles performance period pigment plants plate polarization polymer potential Power Stations practical present problems protection recommended removal resinates resistance Review rosin samples sea water Ships shown shows soil solubility solution steel structure surface Table Technology temperature tests toxicant tube units values weight welded zinc