Journal of Research of the National Bureau of Standards: Engineering and instrumentation. C, Volumes 72-75U.S. Government Printing Office, 1968 |
From inside the book
Results 1-5 of 100
Page 64
... structure . For each electric and magnetic field line contributed by a given element of the disk , there is an equal and opposite field line contributed by an- other element located diametrically opposite the first , and the two cancel ...
... structure . For each electric and magnetic field line contributed by a given element of the disk , there is an equal and opposite field line contributed by an- other element located diametrically opposite the first , and the two cancel ...
Page 67
... structures are , of course , possible in order to increase the value of C of the core and ring , and one may increase ... structure . Type N rf connectors on the two sides of the core ( fig . 4a ) may be used for measuring the biasing po ...
... structures are , of course , possible in order to increase the value of C of the core and ring , and one may increase ... structure . Type N rf connectors on the two sides of the core ( fig . 4a ) may be used for measuring the biasing po ...
Page 72
... structure with the current sensing element in series with the center conductor . Except for the case of thermistors and other beads ( having diameters of the order of 0.1 to 1 mm ) , the current sensing elements are long relative to the ...
... structure with the current sensing element in series with the center conductor . Except for the case of thermistors and other beads ( having diameters of the order of 0.1 to 1 mm ) , the current sensing elements are long relative to the ...
Page 78
... structure ( e.g. , by means of soldering , conductive epoxy cement , clampings , etc. ) . we will allow a conservative width of the electrodes on the disk surface of 15 x 10-3 cm . The computed [ 19 ] equivalent shunt capacity ...
... structure ( e.g. , by means of soldering , conductive epoxy cement , clampings , etc. ) . we will allow a conservative width of the electrodes on the disk surface of 15 x 10-3 cm . The computed [ 19 ] equivalent shunt capacity ...
Page 93
... structure of the reacting ion or reaction complex . The reaction cross section of a given ion with various alkalanes is generally seen to increase with increasing polarizability of the neutral molecule . The actual increase in rate is ...
... structure of the reacting ion or reaction complex . The reaction cross section of a given ion with various alkalanes is generally seen to increase with increasing polarizability of the neutral molecule . The actual increase in rate is ...
Other editions - View all
Common terms and phrases
accuracy admittance alloys analysis application approximately atomic attenuation bolometer Bolovac bridge Bureau of Standards calculated calibration calorimeter capacitance capacitor Chem circuit coaxial coefficient connectors constant creep Cryogenic crystal curves density described detector determined dew point disk effect electrical electron electron probe microanalysis energy equation error evaluation experimental field film flow frequency function heat hydrometer IEEE impedance input Instr Instrumentation Vol Key words laser linear liquid load magnetic materials measurements ment meter method microwave Mössbauer effect Mössbauer spectroscopy National Bureau obtained optical oscilloscope output paper parameters percent Phys precision pressure Proc properties pulse radiation range ratio reference resistance resistors resonance sample shown in figure solution specimen spectra stress surface Tech techniques temperature thermal thermal conductivity thermocouple thermodynamic thiosulfate tion Trans tube tungsten uncertainty values vapor voltage waveguide wet-bulb wet-bulb temperature wire x-ray
Popular passages
Page 28 - In no case does such identification imply recommendation or endorsement by the National Bureau of Standards, nor does it imply that the material or equipment identified is necessarily the best available for the purpose.
Page 46 - THE INSTITUTE FOR BASIC STANDARDS provides the central basis within the United States of a complete and consistent system of physical measurement; coordinates...
Page 25 - Passenger comfort is one of the most important factors to be considered in the design of these facilities and this also applies to the waiting rooms, rest rooms, lunch and dining rooms.
Page 21 - ... (1) nuclear data, (2) atomic and molecular data, (3) solid state data, (4) thermodynamic and transport data, (5) chemical kinetics, (6) colloid and surface properties, and (7) mechanical properties.
Page 82 - These include the development and maintenance of the national standards of measurement and the provision of means and methods for making measurements consistent with these standards...
Page 23 - The procedure uses the x and y coordinates and the individual directions of the minutiae ( ridge endings and bifurcations). The identity of the...
Page 22 - This publication contains a descriptive listing, item by item, of most of the test and calibration work done at the National Bureau of Standards with the respective fees.
Page 16 - Maryland, and by the Division of Biology and Medicine of the United States Atomic...