National Bureau of Standards Miscellaneous PublicationU.S. Government Printing Office, 1964 |
From inside the book
Results 1-5 of 100
Page v
... ANALYSIS HOMOGENEITY TESTING 13 16 17 9 . SAMPLE IDENTIFICATION 21 10 . HEAT TREATMENT 23 • 11 . CHEMICAL ANALYSIS 24 12 . CONSISTENCY TESTING 25 13 . PRECAUTIONS FOR APPLICATION 27 14. ADDENDUM 29 • 15 . REFERENCES 31 • • LIST OF ...
... ANALYSIS HOMOGENEITY TESTING 13 16 17 9 . SAMPLE IDENTIFICATION 21 10 . HEAT TREATMENT 23 • 11 . CHEMICAL ANALYSIS 24 12 . CONSISTENCY TESTING 25 13 . PRECAUTIONS FOR APPLICATION 27 14. ADDENDUM 29 • 15 . REFERENCES 31 • • LIST OF ...
Page 2
... analysis of cast irons including determinations for carbon , phosphorus , and sulfur . This markedly extended the use of spectrochemical analysis in the cast iron field . Also of significant interest has been the increasing appli ...
... analysis of cast irons including determinations for carbon , phosphorus , and sulfur . This markedly extended the use of spectrochemical analysis in the cast iron field . Also of significant interest has been the increasing appli ...
Page 4
... analysis . In white cast iron virtually all of the carbon exists in the combined form and there is essentially no free graphite . Although limited in engineering applications , the white cast iron was considered to be the most ...
... analysis . In white cast iron virtually all of the carbon exists in the combined form and there is essentially no free graphite . Although limited in engineering applications , the white cast iron was considered to be the most ...
Page 16
... ANALYSIS Prior to pouring the molten metal into the mold , two ladle samples to serve for preliminary analysis were obtained by casting into separate containers mounted on the copper plate . These samples were designed to be similar to ...
... ANALYSIS Prior to pouring the molten metal into the mold , two ladle samples to serve for preliminary analysis were obtained by casting into separate containers mounted on the copper plate . These samples were designed to be similar to ...
Page 17
... analysis ; the second sample was sent to a cooperator for preliminary analysis and for application evaluation by comparison with their analyzed spectrochemical * cast iron samples . With the exceptions of carbon , phosphorus , and ...
... analysis ; the second sample was sent to a cooperator for preliminary analysis and for application evaluation by comparison with their analyzed spectrochemical * cast iron samples . With the exceptions of carbon , phosphorus , and ...
Other editions - View all
Common terms and phrases
acid solution add 10 ml aliquot alloy ammonium Analytical Analytical curve assay average beaker boil Bureau of Standards butyl acetate calibration carbon Cartridge Brass cents chemical shift chill-cast chromium composition Cool copper Copper-Base Spectrochemical Standards COPPER-BASE STANDARDS determination dilute Dissolve electrolyte electron probe electron probe microanalysis elements Erlenmeyer flask ferrite Figure filter free-cutting brass fumes glass grain heat homogeneity inclusions Institute for Materials Laboratory Low-Alloy Steel manganese Materials Research mean free path measurement metal method microns ml of H2SO4 ml of HNO3 ml of water Mossbauer National Bureau NBS Misc NBS Miscellaneous Publication NBS Spectrometric nickel nitric acid obtained oxide paper pearlite percent photometric precipitate procedure Publ Reagents sodium sodium nitroprusside spectrometer standard deviation Standard Reference Materials sulfate sulfuric acid Technology titration Transfer uranium Vacuum fusion values vanadium viscosity volumetric flask wash weight white cast iron x-ray zinc