" Electric motor-driven vapor compression heat pumps with supplemental electrical resistance heat shall be sized to provide by compression at least 60 percent of the calculated annual heating requirement for the manufactured home being served. A control... "
Energy Conservation in Federal and Federally Assisted Buildings: Hearings ... - Page 540
by United States. Congress. Senate. Committee on Public Works. Subcommittee on Public Buildings and Grounds - 1975
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

1979 - 854 pages
...Heat Pumps 240-74. Electric motor-driven vapor compression heat pumps with supplemental electrical resistance heat shall be sized to provide by compression...the calculated annual heating requirement for the mobile home being served. A control shall be provided and set to prevent operation of supplemental...
Full view - About this book

The Code of Federal Regulations of the United States of America

1982 - 368 pages
...Heat Pumps 240-74. Electric motor-driven vapor compression heat pumps with supplemental electrical resistance heat shall be sized to provide by compression...the calculated annual heating requirement for the mobile home being served. A control shall be provided and set to prevent operation of supplemental...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

2001 - 392 pages
...Heat Pump Equipment. Electric motor-driven vapor compression heat pumps with supplemental electrical resistance heat shall be sized to provide by compression...least 60 percent of the calculated annual heating requirements for the manufactured home being served. A control shall be provided and set to prevent...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

1997 - 386 pages
...Heat Pump Equipment. Electric motor-driven vapor compression heat pumps with supplemental electrical resistance heat shall be sized to provide by compression...least 60 percent of the calculated annual heating requirements for the manufactured home being served. A control shall be provided and set to prevent...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

1985 - 916 pages
...Heat Pumps 240-74. Electric motor-driven vapor compression heat pumps with supplemental electrical resistance heat shall be sized to provide by compression...the calculated annual heating requirement for the manufactured home being served. A control shall be provided and set to prevent operation of supplemental...
Full view - About this book

The Code of Federal Regulations of the United States of America

1987 - 504 pages
...Electric motor-driven vapor compression heat pumps with supplemental electrical resistance heat shaU be sized to provide by compression at least 60 percent...the calculated annual heating requirement for the manufactured home being served. A control shall be provided and set to prevent operation of supplemental...
Full view - About this book

NBSIR.

1976 - 120 pages
...automatically-controlled heat outlets or fixtures in all the spaces in a zone. The rationale for not recomnending a differential reduction of heat loss even greater...70 Design Temperature, °F SPF > 35 > 2.25 20 to 35 > 2,.0 0 to 20 > 1.5 -20 to 0 > 1.25 SPF = X Y+Z X = heat delivered to space during heating season,...
Full view - About this book

The Code of Federal Regulations of the United States of America

1990 - 440 pages
...compression heat pumps with supplemental electrical resistance heat shall be sized to provide by cojnpression at least 60 percent of the calculated annual heating requirement for the manufactured home being served. A control shall be provided and set to prevent operation of supplemental...
Full view - About this book

Manufactured Home Construction and Safety Standards and Procedural and ...

Barry Leonard - 2000 - 212 pages
...Heat Pump Equipment. Electric motor-driven vapor compression heat pumps with supplemental electrical resistance heat shall be sized to provide by compression...least 60 percent of the calculated annual heating requirements for the manufactured home being served. A control shall be provided and set to prevent...