Research and Innovation in the Building Regulatory Process: Proceedings of the First NBS/NCSBCS Joint Conference, Held in Providence, Rhode Island, on September 21-22, 1976, in Conjunction with the Ninth Annual Meeting of the National Conference of States on Building Codes and Standards (NCSBCS), Inc, Volume 13Patrick W. Cooke U.S. Department of Commerce, National Bureau of Standards, 1977 - 504 pages |
From inside the book
Results 1-5 of 19
Page 289
... area check , is an example of a very simple decision table . The only condition is that the actual story area be less than the total allowable story area , and the two possible ... Area Check X The table is read rule by rule , " If 289.
... area check , is an example of a very simple decision table . The only condition is that the actual story area be less than the total allowable story area , and the two possible ... Area Check X The table is read rule by rule , " If 289.
Page 290
... area , then the single story area check is satisfied , if it is not , then the check is violated . " The decision table shown below for data item number 46 , the allowable area increase for special occupancy situations ( 506 ( b ) ...
... area , then the single story area check is satisfied , if it is not , then the check is violated . " The decision table shown below for data item number 46 , the allowable area increase for special occupancy situations ( 506 ( b ) ...
Page 291
... check- ing necessary to verify a rule . Reference 4 contains more ... area shown in Table 5C . The table is not converted from its present tabular ... area increase ( 506 ( b ) ) is shown along with the decision tree derived from it ...
... check- ing necessary to verify a rule . Reference 4 contains more ... area shown in Table 5C . The table is not converted from its present tabular ... area increase ( 506 ( b ) ) is shown along with the decision tree derived from it ...
Page 292
... area check Ingredient nodes : Data item 4 , actual story area Data item 6 , allowable story area Portion of information network 2 4 6 Computer representation of the network 2 SINGLE STORY AREA CHECK : 4 actual story area 6 allowable ...
... area check Ingredient nodes : Data item 4 , actual story area Data item 6 , allowable story area Portion of information network 2 4 6 Computer representation of the network 2 SINGLE STORY AREA CHECK : 4 actual story area 6 allowable ...
Page 294
... area check seems to overwhelm one . The maze is not apparent on a first reading of Section 505 , but begins to grow as the cross references to other sections , both explicit and implicit , are explored . For example , the fairly ...
... area check seems to overwhelm one . The maze is not apparent on a first reading of Section 505 , but begins to grow as the cross references to other sections , both explicit and implicit , are explored . For example , the fairly ...
Other editions - View all
Common terms and phrases
Administration agency Allowable Area Increase allowable story area analysis ANSI application architect architectural AREA CHECK Area Separation Wall ASHRAE basic building community building officials building regulations building regulatory Bureau of Standards City code enforcement code requirements construction contractor cost criteria DECISION TABLE design review dwelling effectiveness electrical energy conservation Engineers environment environmental evaluation existing buildings Figure Fire Resistance GFCI groups handicapped housing impacts industry innovation installation Institute knowledge materials measure method metric minimum Mobile Home model building codes model codes National Bureau National Electric Code NIBS North Carolina occupancy Open Parking Garage organizations parameters percent performance attributes performance standards physical plumbing potential Prefabricated home problem professional programs projects regulatory process reported residential roof safety Section solar heating specific structure technical Technology Uniform Building Code units variables venting Washington