California Contractors License Law and Reference BookContractors' State License Board, 1957 |
From inside the book
Results 1-3 of 42
Page 216
... Stairway computation fireproof buildings A - H buildings A - H ( c ) The width of each stairway shall be measured in the clear of all projections except ( 1 ) the baseboard , and ( 2 ) one handrail or newel post on each side projecting ...
... Stairway computation fireproof buildings A - H buildings A - H ( c ) The width of each stairway shall be measured in the clear of all projections except ( 1 ) the baseboard , and ( 2 ) one handrail or newel post on each side projecting ...
Page 217
... stairway in any building shall abut on more Elevator than one side of an elevator shaft , except on the lowest and A - H topmost stories , and then only if the stairway is so located that it can be approached from the street entrance ...
... stairway in any building shall abut on more Elevator than one side of an elevator shaft , except on the lowest and A - H topmost stories , and then only if the stairway is so located that it can be approached from the street entrance ...
Page 218
California. Width A - H - D Exterior stairways A - H Space under stairway A - H Roof egress A - H Penthouse : Materials A - H Door A - H Door open- ing A - H Scuttle A - H When the width of a stairway exceeds 88 inches , there shall be ...
California. Width A - H - D Exterior stairways A - H Space under stairway A - H Roof egress A - H Penthouse : Materials A - H Door A - H Door open- ing A - H Scuttle A - H When the width of a stairway exceeds 88 inches , there shall be ...
Contents
C2A23 | 6 |
Types of Questions | 12 |
Business and Professions Code Sections 116 and 162 | 34 |
11 other sections not shown
Other editions - View all
Common terms and phrases
action affidavit Amendment filed apartment house appliances applicable to buildings approved August 17 awarding body Berkeley bond chapter claim of lien claimant classification compensation insurance concrete construction contractor whose principal deed of trust division dwelling employee enforcement agency examination filed for record fire door fire escape fire-resistive fixtures floor area furnished guest room gypsum hearing house or hotel inches injury inner court installed ister joists labor less license materials metal lath minimum misdemeanor NOTE-Is applicable notice occupancy officer thereof owner paid party payment penalty permit person plaster prescribed principal contracting business proposed decision public hallway pursuant rear yard registrar renewal Retroactive section roof Safety Orders section number skill to intelligently specialty contractor specifications square feet stairway stories in height structure subcontractor subdivision surety tion UNIVERSITY OF CALIFORNIA unless vent shaft ventilation violation wages walls water-closet width window